  • Page 1 Digital High / Low Thermostat INSTALLATION AND OPERATION PNEG-1499 PNEG-1499 Date: 2-1-06 PNEG-1499 High / Low Thermostat...
  • Page 2: Check List

    _____ g. Value 7 set to ( H2 ) _____ 3. All items included in packaging. _____ 4. Safety Decal Installed on side of Thermostat _____ 5. Aesthetic appearance _____ 6. Manual _____ 7. Vendor Instruction Sheet Tester Signature___________________________________ Date_________________________ PNEG-1499 High / Low Thermostat...
  • Page 3: Table Of Contents

    Roof Damage Warning and Disclaimer .......... 8 Installation ....................9 Thermostat Connection to Standard Heater Control ....... 10 Thermostat Connection to Deluxe Heater Control ........11 Programming Setpoint Values ..............12 Parts ..................... 13 Appendix ....................14 Warranty ....................15 PNEG-1499 High / Low Thermostat...
  • Page 4: Safety

    CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage. NOTE indicates information about the equipment that you should pay special attention to. PNEG-1499 High / Low Thermostat...
  • Page 5 PREPARE FOR EMERGENCIES Be prepared if fire starts. Keep a first aid kit and fire extinguisher handy. Keep emergency numbers for doctors, ambulance service, hospital, and fire department near your telephone. PNEG-1499 High / Low Thermostat...
  • Page 6 INSTALL & OPERATE GAS-FIRED EQUIPMENT PROPERLY Fuel supply should be installed by a qualified gas technician and must meet local and state codes for gaseous fuel supplies. Disconnect and lock out all fuel sources before servicing equipment . PNEG-1499 High / Low Thermostat...
  • Page 7: Safety Decals

    SAFETY DECALS Safety decals should be read and understood by all people in the grain handling area. If a decal is damaged or is missing contact: The GSI Group, Inc. 1004 E. Illinois St. Assumption, IL 62510 217-226-4421 A free replacement will be sent to you.
  • Page 8: Roof Damage Warning And Disclaimer

    It is the plan of The GSI Group to improve its ment, or who are in the dryer area. Avoid any alter- product whenever possible and practical to do so. We ations to the equipment.
  • Page 9: Installation

    9. Insert the Sensor into the 1/2” hole and reattach the mounting plate using the S-280 screws. 10. Caulk the area around the mounting plate to seal any openings. Mount the Sensor approximately 24” to the RIGHT of the transition. PNEG-1499 High / Low Thermostat...
  • Page 10: Thermostat Connection To Standard Heater Control

    5. 5. Connect the ORANGE Stage 1 Common wire to terminal 8. 6. Connect the RED Stage 2 Common wire to terminal 6. 7. Connect the GREEN Stage 2 N/O wire to the high/low light. PNEG-1499 High / Low Thermostat...
  • Page 11: Thermostat Connection To Deluxe Heater Control

    2. Connect the BLACK 120VAC power wire to terminal 20. 6. Connect the RED Stage 2 Common wire to terminal 13. 3. Connect the WHITE Neutral wire to terminal 19. 7. Connect the GREEN Stage 2 N/O wire to terminal 12. PNEG-1499 High / Low Thermostat...
  • Page 12: Programming Setpoint Values

    Press the SET key again. “DIF2” should now flash at the left side of the screen. Press the UP arrow to increase or the DOWN arrow to decrease the differen- tial to the desired setting. PNEG-1499 High / Low Thermostat...
  • Page 13: Parts

    THERMOSTAT 2-STAGE DIGITAL FH-1309 LOCK NUT 1/2" #401 ARL. FH-1310 CONNECTOR 1/2" 12 ft WR-186SEOW WIRE CLM 18/6 SEOW CTRL CBL S-280 SCREW SDS #10-16x5/8 HWH ZN HF-8058 SENSOR MOUNTING PLATE-HILO T/S HF-8057 CONNECTOR STRAIGHT CORDGRIP PNEG-1499 High / Low Thermostat...
  • Page 14: Appendix

    To Correct: This condition cannot be field repaired. Replace the control. Appears if calibration mode has been entered. To Correct: Remove power to the control for at least five seconds. Reapply power. If the CL message still appears, replace the control. PNEG-1499 High / Low Thermostat...
  • Page 15: Warranty

    WARRANTY THE GSI GROUP, INC. ("GSI") WARRANTS ALL PRODUCTS MANUFACTURED BY GSI TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USAGE AND CONDITIONS FOR A PE- RIOD OF 12 MONTHS AFTER RETAIL SALE TO THE ORIGINAL END USER OF SUCH PRODUCTS. GSI'S...
  • Page 16 This Equipment shall be installed in accordance with the current installation codes and applicable regulations which should be carefully followed in all cases. Authorities having jurisdiction should be consulted before installation occurs. Revisions: February 2006 PNEG-1499 High / Low Thermostat...