YOU MUST USE SUPPLIED ABS PIPE FOR FIRST 84" OF EXHAUST PIPING. ADDITIONAL PIPING
CAN BE ABS OR PVC. YOU MUST SUPPORT ALL PIPING, THE APPLIANCE IS NOT INTENDED TO
SUPPORT VENTINGPIPES.
PLEASE NOTE: THE METHODS DESCRIBED ARE SUGGESTED GENERIC METHODS ONLY. SPECIFIC JOB SITE
OBSERVATIONS AND SIZING MAY REQUIRE ALTERNATE INSTALLATION METHODS.
REFER TO FIG. 3A PG. 21 FOR FURTHER DETAILS.
1)
Never vent into a walkway or patio area, or any alley, or otherwise public area less than 7' from the ground.
2)
never install a heat saver or similar product to capture waste heat from exhaust.
3)
Always have a vent location at least 1' above maximum snow level.
4)
Always have vent 1' above ground level, away from shrubs and bushes.
5)
Always be at least 2' horizontally from doors or windows. (36" for Canadian installations. Refer to Fig. 3A pg. 21.)
6)
Always have vent at least 3' from inside corner of outside walls.
7)
Maintain at least 4' clearance to electric, bas meters, and exhaust fans or inlets.
8)
VERY IMPORTANT!! Inlet air must be taken from outside of building, next to exhaust outlet, no closer than 8".
9)
Always place screens in all the intake and exhaust openings to prevent foreign matter from entering the Voyager.
10) The vent intake and exhaust must be properly cleaned and glued for pressure tight joints.
11) The vent intake and exhaust must be properly cleaned and glued, for pressure tight joints. Several methods for
venting the Super-E can be found on pages 22 and 23. Use the following layout as a guideline; certain site
conditions such as multiple roof lines/pitches may require venting modifications – consult factory. The air inlet must
be a minimum of 1' vertically above the maximum snow level of 24", whichever is greater. The air inlet must also be a
minimum of 10' horizontally from the roof, and terminated with a tee. The exhaust must be minimum of 24" above the
air inlet opening, and terminated with a coupling. It is very important that there are no other vents, chimneys, or air
inlets in any direction for at least 4'. Please refer to typical venting on pages 22 and 23. ALL VENTING MUST BE
PROPERLY SUPPORTED, AS THE VOYAGER IS NOT INTENDED TO SUPPORT ANY VENTING
WHATSOEVER. All piping, glue, solvents, cleaners, fittings, and components, must conform to ASTM (American
Society for Testing and Materials), and ANSI (American National Standard Institute).
12) It is recommended that you use one of the mentioned vent kits specifically for Super-E installations; either
KGAVT0501CVT (2 in.) or KGAVT0601CVT (3 in.) or the V1000.
NOTE: CLEARANCE SHALL BE IN ACCORDANCE WITH LOCAL INSTALLATION CODES AND TH REQUIREMENTS OF
THE GAS SUPPLIER.
TYPICAL VENTING
CAUTION
PAGE: 20