GENERATOR STORAGE
If you plan on storing your generator for an extended period of time, the following steps should be followed;
1) Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage.
2) Run engine at least 5 minutes after adding fuel stabilizer to allow it to enter the fuel system. NOTE: If a fuel stabilizer is not used, it is highly
recommended to start the engine and operate at idle until all remaining fuel is gone and engine stops, this will prevent gum deposits from
forming in the carburetor and causing possible malfunction of the engine.
3) Drain engine oil from engine as described in "Engine Oil Replacement".
4) Pull the recoil starter handle gently until resistance is felt. At this point, the piston is coming up on its compression stroke and both intake and
exhaust valves are closed. Storing engine in this position will help protect it from internal corrosion.
PROBLEM
Engine will not start
Engine is running but no AC output
Repeated circuit breaker tripping
Generator overheating
Engine runs well but gets bogged
down when loads are connected
PARTS DIAGRAM & PARTS LISTS
Refer to the Parts section of the King Canada web site for the most updated parts diagram and parts list.
STORAGE & TROUBLESHOOTING
CAUSE
1. Low on fuel or oil.
2. Faulty spark plug.
3. Fuel shut-off valve is closed.
4. Unit loaded during start-up.
5. Spark plug wire loose.
1. Faulty receptacle.
2. Circuit breaker tripped.
3. Defective capacitor.
4. Faulty power cord.
1. Overload.
2. Faulty cords or equipment.
1. Generator overloaded.
2. Insufficient ventilation.
1. Electrical short in connected item.
2. Overloaded.
CORRECTION
1. Add fuel or oil.
2. Replace spark plug.
3. Open fuel shut-off valve.
4. Remove load from unit.
5. Attach wire to spark plug.
1. Have Service Center replace.
2. Reset breaker.
3. Have Service Center replace capacitor.
4. Repair or replace cord.
1. Reduce load.
2. Check for damaged, bare, or frayed wires
on equipment. Replace.
1. Reduce load.
2. Move to adequate supply of fresh air.
1. Disconnect shorted load.
2. Reduce load.