installation diagrams - top inlet/outlet usage

Use of the top inlet water connection requires an inlet dip tube
(refer to figure 19). The tube is supplied in the heater. Follow
caution labels if applying heat to this fitting. Do not allow pipe
dope to contact the plastic tube during installation.
tuBe inlet installation
figure 19.
temperature
setting
safe use temperature at fiXtures. see water
temperature Control and miXing ValVes on
page 12. if higher preheat temperatures are
neCessary to oBtain adeQuate Booster output,
add an anti-sCald ValVe for hot water supplied
to fiXtures.