AD-9 Operating Instructions
Page 13

Operating Your Amplifier: Front Panel Controls and Indicators

1: Power Switch: This single pole switch turns the amplifier fully off (but does NOT isolate it
from the mains supply).
2: Power LED: This indicates when the amplifier is active. This does NOT indicate the
presence of a mains supply when the power switch is OFF.
3: Signal Meter and OCM indicators: These LED bar graphs show instantaneous level on
each channel to indicate proximity to the limiter threshold. Note that if the PRC system is in
operation on any channel, this will affect the readout shown on the respective meter.
The red LED in the meter will illuminate when the limiter threshold has been reached and
limiting is occurring. The output current monitor (OCM) may activate to limit the output
current of the amplifier channel - this can occur even if the amplifier has not reached clipping
point.
The OCM indicator can operate independently of the bar graph meter. Typical conditions that
may trigger the OCM circuitry would be very low load impedance, or high subsonic or VHF
levels.
4: Attenuation Controls: These are analogue controls allowing precise level settings. Note
that in bridged (mono) mode some controls may be inactive.
5: Link LED: This indicates if the channel is linked to its immediate neighbour. If this is
illuminated, the attenuation control of the channel to the immediate right will not function as
both channels are being fed from the left hand channel. The link switches are on the rear
panel – see page 15 for details.
6:
PRC LED:
This illuminates if the Power Reduction Control has been enabled on the
respective channel. PRC switches are on the rear panel – see page 5 for details.
7: A/P (Auto Protect) LED: If a condition exists, either internally or externally, that could
cause damage to either the amplifier or the speakers, the protection circuit will disengage the
outputs and the A/P LED will illuminate. The amplifier will continue to be monitored and
depending on the type of fault, will either reset after the fault has cleared or require manual
resetting by switching off at the mains switch and then on again after a few seconds.