Air leak from safety valve.
Pressure
reading
on
regulated
pressure
drops when an accessory is
used.
Excessive tank pressure.
Motor will not start.
Excessive
moisture
discharge air.
Air leaks from the tank body
or tank welds.
Operate the safety valve manually by pulling on the ring. If the valve continues to
leak when in the closed position, it should be replaced.
the
If there is an excessive amount of pressure drop when the accessory is used,
gauge
replace the regulator.
NOTE:
Adjust the regulated pressure under flow conditions (while accessory is being used).
It is normal for the gauge to show minimal pressure loss during initial use of the tool.
Move the Auto-On/Off lever to the Off position. If the unit doesn't shut off, unplug it
from the power source and contact a service technician.
Make sure power cord is plugged in and the switch is on. Inspect for the proper size
fuse in your circuit box. If the fuse was tripped reset it and restart the unit. If repeated
tripping occurs, replace the check valve or contact your service technician.
in
the
Remove the water in the tank by draining after each use. High humidity
environments will cause excessive condensation. Utilize water filters on your air line.
NOTE:
Water condensation is not caused by compressor malfunction. Be sure the
compressor's air output is greater than your tool's air consumption rate.
Never drill into weld or otherwise modify the air tank or it will weaken. The tank can
rupture or explode. Compressor cannot be repaired. Discontinue use of the air
compressor.