OPERATION PROCEDURES

Before First Start-up Procedures
1. Fill proper oil before operating compressor.
2. Turn regulator knob fully clockwise (to the right) to open air flow.
3. Turn on/off switch to OFF position.
4. Plug in power cord.
5. Turn on/off switch to AUTO position and run compressor for 30 minutes.
6. Turn on/off switch to OFF position.
7. Unplug power cord.
8. The compressor is now ready for use.
Daily Start-Up Procedures
1. Fill proper oil before operating compressor
2. Turn on/off switch to OFF position.
3. Check the air compressor visually for any damage or obstruction.
4. Close the drain valve.
5. Turn regulator knob fully counter clockwise (to the left) to close air flow.
6. Connect air hose to outlet of regulator.
7. Plug in power cord.
8. Turn on/off switch to AUTO position and let compressor run until it reaches automatic shutoff pressure.
9. Attach tire chuck or tool to end of hose.
10. Turn regulator knob clockwise (to the right) to desired pressure of tool being used.
11. The air compressor is now ready for use.
Improper installation of the grounding plug can result in a risk of electric shock. If repair or
replacement of the cord or plug is necessary, do not connect the grounding wire to either flat blade terminal. The wire
with insulation having an outer surface that is green with or without yellow stripes is the grounding wire. Check with a
qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to
whether the product is properly grounded. Do not modify the plug provided; if it will not fit the outlet, have the proper
outlet installed by a qualified electrician.
Compressor parts may be hot even if the unit is stopped. Keep fingers away from a running
compressor; fast moving and hot parts will cause injury and/or burns.
Never remove or attempt to adjust safety valve. Keep safety valve free from paint and other
accumulations.
Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released.
Daily Shut-Down Procedures
1. Set the Auto-On/Off lever to the Off position.
2. Unplug the power cord from the receptacle.
3. Set the outlet pressure to zero on the regulator.
4. Remove any air tools or accessories.
5. Open the drain valve allowing air to bleed from the tank. After all of the air has bled from the tank, close the drain
valve to prevent debris buildup in the valve.
Water that remains in the tank during storage will corrode and weaken the air tank, which could cause the tank to
rupture. To avoid serious injury, be sure to drain the tank after each use or daily.