ATENT OTICE These instructions generally describe the installation, operation and maintenance of the Bio-Logic ® Pure Water Pack™. Questions that are not specifically answered by these instructions should be directed to the Factory. Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent damage.
SAFETY WARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this unit. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property. This is the safety alert symbol.
The ultravio- ® let intensity is the amount of energy, per unit time, emitted by the germicidal lamp. The operation of the Bio-Logic is as follows: Water enters the purifier and flows into the annular space between the quartz sleeve and the chamber wall.
• • Filter Housing Wrench with the lamp packed separately. Keep the lamp • Operating Instructions aside for installation once the Pure Water Pack™ has been properly installed. ® Figure 2 - Bio-Logic Pure Water Pack™ - Drinking Water System...
6-inches on the backside of the water purifier, and a minimum of 2-inches free space under the filter housings, to allow for housing removal, when changing filter cartridges. ® Figure 1 - Bio-Logic Pure Water Pack™ Installation The water purifier is intended for indoor use only. The water purifier should be protected from the elements and from temperatures below freezing.
ADDLE ALVE NSTALLATION Check with the local public works department for plumbing codes. Follow all local plumbing codes when installing components of this system. The system comes supplied with a saddle valve and mounting hardware and is intended to be used on 3/8 inch to 1/2 inch copper tubing, and should be connected to the cold water line only.
Run the tubing, connected to the saddle valve, to the inlet fitting of the sediment filter. ® b. Run the precut 24" tubing from the outlet of the carbon filter, to the inlet of the Bio-Logic water purifier. ®...
UBING NSTALLATION • Measure and cut the tubing to desired length. Leave enough slack in the tubing so the system can be easily removed, if necessary. Cut the tubing square; remove all burrs and sharp edges. • Insert tubing into fitting; push until it reaches the tube stop. Avoid kinking or stretching tubing. Check that tubing is secure;...
3. Release the pressure in the filter housing, by pressing the red pressure release button, located on top of each filter ® housing. See Figure 2 on page 6 - Bio-Logic Pure Water Pack™ - Drinking Water System for location.
NSTALLATION OR EPLACEMENT Figure 7 - Lamp Replacement Step 1 - Remove Ground Connector Disconnect power to Pure Water Pack™, and remove ground connector from the chamber. Remove easy-off end cap by pulling cap off static gland nut. Carefully withdraw lamp approximately 2" from chamber. Step 2 - Remove End-Cap While holding lamp end, remove lamp socket from exposed lamp end.
Considerable force may be required to pull purifier from the mounting clips. Exercise extreme care when removing purifier. ® 2. Remove the tubing from the inlet and outlet fittings of the Bio-Logic Ultraviolet Water Purifier. See “Tubing Removal” for the proper method of removing the tubing.
TROUBLESHOOTING WARNING: Always disconnect power to the water purifier before performing any service or maintenance. IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel. Table 2 - Troubleshooting Problem Possible Cause Corrective Action Purifier not operating. No electrical power…...
® Hauppauge, New York, 11788 Bio-Logic Pure Water Pack™ before installing or using this unit. is a product of superior quality and If after reading the manual you still Tel: 631.273.0500...