TIMERS AND MODE SECTIONS-(S1 and S2)
FULL SPEED RUN TIMER- SWITCH PACK S1 (1-4)
approximately 1.5 seconds. Changing settings will adjust fast run timer by 1/8 second increments.
(Example: #2 on equals .25 seconds, #4 on equals 1 second. #2 and #4 on equals 1.25 seconds)
1/8ths SECONDS 1 2 4 8
S1
FAST RUN TIMER 1-4
MODE SELECTIONS- SWITCH PACK S1 (5-8)
SWITCH - 5. ON -Will allow J5 input #4 to operate as a pulse open/pulse close function.
SWITCH - 6 . ON -Will fire relay if gate is pushed UP from closed limit, used with clutch option. Also
ANTI TAIL-GATE ALARM, if tail gating is detected by close loop, K1 relay will fire. When using clutch
option, turning on S1-6 & S2-7, gate will close by timer whenever forced up.
SWITCH - 7 . USED TO ENABLE ARM TO WORK IN REVERSE DIRECTION, SEE PAGE 11.
SWITCH - 8 .Off will make K1 relay activate during open cycle (use with buzzers, counters, etc..) On
will pulse K1 relay when OPEN LIMIT (OLS) is reached (activates a swing or slide gate its lane).
(SEE ALSO PAGE 3 - RELAY OUTPUT-K1 .
CLOSE TIMER- SWITCH PACK S2 (1-5)
On the MEGA-ARM the switches 1-5 on S2 are for the closing time delay to select the period of time
that the gate stays open after the obstruction sensor has reversed and re-opened the arm or if the
S2-7 timer to close is turned on. The default will keep the gate up for 4 seconds to allow the vehicle
to be moved from the gate arm path. Changing settings 1 - 5 will increase or decrease this hold open
time. The default of 3 ON and 1,2,4,5 OFF will provide a 4 second close time delay .
SECONDS-------- 1
S2
1 2
CLOSE TIMER 1-5 | MODE SELECTION 6-8
MODE SELECTIONS- SWITCH PACK S2 (6-8)
SWITCH - 6. INPUT MEMORY. Activates multiple vehicle memory at aux input terminal #4 on J5.
SWITCH - 7 AUTO CLOSE TIMER. Default is OFF. On will close gate by timer when all inputs are
cleared. Time is set by using S2 1-5 switches (WARNING-Special care should be used to avoid arm
from closing on cars. Use safety loops, stop loops, photo beams and a long enough time delay)
(Note: Can be used with multiple vehicle memory buffer to allow gate to close and reset count
memory to zero. When using clutch option, turning on S1-6 & S2-7, gate will close by timer whenever
forced up.
SWITCH - 8 AUTO OPEN ON POWER FAILURE. When switch number 8 is in the ON position, the
operator will automatically open the gate approximately 15 seconds after the loss of power. Once
power is restored the operator will resume normal operation after the first car passes closing loop or if
close timer S2-7 in turned on (It is recommended to allow the gate to close by loop, not by timer).