Telular PHONECELL SX4e CDMA Technical Manual

800 mhz and 1900 mhz cdma fixed wireless terminal

Advertisement

Quick Links

P
®
SX4e CDMA
HONECELL
F
W
T
IXED
IRELESS
ERMINAL
800 MH
CDMA
Z
and
1900 MH
CDMA
Z
V
C
OICE
OMMUNICATION
C
F
/D
OMPUTER
AX
ATA
A
F
(O
)
NALOG
AX
PTIONAL
T
M
ECHNICAL
ANUAL
02/13/02
Part Number 56023001

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PHONECELL SX4e CDMA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telular PHONECELL SX4e CDMA

  • Page 1 ® SX4e CDMA HONECELL IXED IRELESS ERMINAL 800 MH CDMA 1900 MH CDMA OICE OMMUNICATION OMPUTER NALOG PTIONAL ECHNICAL ANUAL 02/13/02 Part Number 56023001...
  • Page 2: Contents

    PRODUCTS ("Product") These Terms and Conditions are a legal contract between you and Telular Corporation for the title to and use of the Product. BY RETAINING AND USING THE PRODUCT AFTER RECEIPT OF IT, YOU AGREE TO THE TERMS AND CONDITIONS INCLUDING WARRANTY DISCLAIMERS, LIMITATIONS OF LIABILITY AND INDEMNIFICATION PROVISIONS BELOW.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Contents ........................2 Safe Operation Instructions ..................2 Important Notices ......................2 Installation........................4 Antenna Location and Setup..................4 Optional Wall-Mount Instructions ................4 Connect Your Phonecell to AC Power ...............5 Emergency Battery Backup ..................5 Plug in Your Telephone ....................5 Phonecell SX4e Operation...................6 How to Use the LED Status Indicators ..............6 How to Place a Call ....................6 How to Receive a Call ....................7...
  • Page 4: Installation

    INSTALLATION Antenna Location and Setup The Phonecell SX4e comes with a standard spike antenna (TNC). External options for improved sig- nal strength include magnetic mount (TNC), patch panel (N), or yagi (TNC) - See Figure 1. For opti- mal signal strength, choose an antenna location that is above ground and as close to windows (or exterior walls) as possible - See Figure 2.
  • Page 5: Connect Your Phonecell To Ac Power

    Connect Your Phonecell SX4e to AC Power 1) Connect the barrel connector of the power supply to the AC power input receptacle of the Phonecell SX4e - See Figure 5. 2) Plug the power supply into the AC socket. 3) Press and hold the power button until the power LED is green - See Figure 5 and Figure 8. 4) Check the cellular signal strength and move the unit (or external antenna) until you achieve the best signal possible - see the Received Signal Strength section of this guide.
  • Page 6: Phonecell Sx4E Operation

    PHONECELL SX4e OPERATION How to Use the LED Status Indicators Received Signal 1) Power-on the unit (see the Strength Indicator Connect Your Phonecell to AC (RSSI) Power section of this manual). 2) The LED indicators on the front of the SX4D will turn ON. The following tables describe the modes and operation of the indicators - See Figure 8.
  • Page 7: How To Receive A Call

    How to Receive a Call When your telephone rings, pick up the handset and begin talking. NOTE: If you hear an incoming call while picking up the handset, you can receive the call by hanging up (placing the handset on the cradle) immediately. This will cause the phone to start ringing. How to End a Call Hang up the phone (place the handset onto the cradle).
  • Page 8: Sending Digital Fax

    For specific digital fax/data setup procedures, see Appendix A - How to Setup Your PC Serial Ports for Phonecell Digital Fax/Data. To PC Serial Port DB-9 cable and PC serial port have 9 PIN connections DB-9 (female) to DB-9 (male) Cable DB-25 cable and PC To DB-9 Data Port on FWT serial port have 25...
  • Page 9: Receiving Digital Data

    Receiving Digital Data Once the SX4e is set up as a Standard 19,200 bps Modem, there are two command options for receiving digital data through the SX4e. These options are programmed by going off-hook with a DTMF telephone connected to the SX4e and entering the following commands: 1) Press 9 6 to set "always on"...
  • Page 10: Phonecell Sx4E Set-Up

    PHONECELL SX4e SET-UP Phonecell SX4e Set-up Overview The Phonecell SX4e has several options for unique customer or network applications. These options are stored in the unit’s non-volatile memory and are retained during power cycling. In the following sections, an <entered value> is comprised of the digits 0 through 9. The digits “ ”...
  • Page 11: How To Set Caller Id Mode

    How to Set Caller ID Mode If the phone connected to the SX4e is caller ID-enabled, you can set the SX4e to display the caller number or name on the phone. Use the following key sequence to set Caller ID Mode. Press: 7 # <caller ID type>...
  • Page 12: The Nam Menu

    THE GENERAL MENU The following programming commands are accessed while in the Technician Programming Mode. How to Choose the Service Option (SO) Use the following key sequence to choose the desired service option. After entering Technician Programming Mode and then the General Menu, Press: 1 # 3 # <SO>...
  • Page 13 How to Enter A Phone Number Use the following key sequence to enter the unit’s phone number. After entering Technician Programming Mode and then the NAM Menu, Press: 2 # 1 # 3 # <phone number> # You may enter a ten-digit phone number. How to Enter the Access Overload Class (ACCOLC) (Access Priority Setting) Use the following key sequence to enter the ACCOLC.
  • Page 14 How to Enter the Home SID Number Use the following key sequence to enter the home SID number. After entering Technician Programming Mode and then the NAM Menu, Press: 2 # 1 # 1 2 # <00000> # The brackets indicate that you may enter a five-digit Home SID number . If more than 5 numbers are entered, the Phonecell will reject it and return to the previously stored number.
  • Page 15: Phonecell Sx4E Troubleshooting

    Standard. The design of your Telular Phonecell SX4e complies with this updated Standard. Of course, if you want to limit RF exposure even further than the updated ANSI Standard, you may choose to control the duration of your calls and operate your phone in the most power-efficient manner.
  • Page 16 Safe Operation Requirement Do not operate your Phonecell SX4e when any person is within 1 inch (2,5 cm) of the antenna. emperature Environment Operating Temperature: From -20°C to +60°C ; Up to 95% relative humidity (non-condensing). Storage Temperature: From -25°C to +75°C; Up to 95% relative humidity (non-condensing). Antenna Care and Replacement Do not use the Phonecell SX4e with a damaged antenna.
  • Page 17: Warranty

    (15) months from date of shipment from Telular. Telular, at its option, shall at no charge either repair, replace or refund the purchase price of the Product during the warranty period, provided it is returned by Buyer in accordance with the terms of this warranty to the Telular designated repair center.
  • Page 18 Laws in the United States and other countries preserve for Telular certain exclusive rights for copyrighted Telular software such as the exclusive rights to reproduce in copies and distribute copies of such Telular software. Telular software may be copied into, used in and redistributed with only the Product associated with such Telular software. No other use, including without limitation, disassembly of such Telular software or exercise of exclusive rights in such Telular software is permitted and Telular reserves all rights not expressly granted in this Limited Commercial Warranty.
  • Page 19: Appendix A: How To Setup Pc Serial Ports For Phonecell

    APPENDIX A: HOW TO SETUP PC SERIAL PORTS FOR PHONECELL DIGITAL FAX/DATA Requirements · CDMA account with your network service provider including a Data/Fax facility. · PC/Laptop/ Notebook with Com Port. · Windows 95/98 NOTE: When all of the above have been satisfied, you may proceed. Modem Setup 1) Power on your PC/laptop and start Windows 95/98.
  • Page 20 4) The install new modem window may appear asking for the type of modem to install. Click on "Other" followed by clicking the NEXT button. If this window does not appear, go to Step 5. 5) The install new modem window will appear. Then, click on the "Don't detect my modem option" followed by clicking the NEXT button.
  • Page 21 6) The install new modem will update again to select the manufacturer and modem model. Click on "Standard Modem Types" from the manufactures list followed by "Standard 19200 bps Modem" from the model list. Then click on the NEXT button. 7) The install new modem will update to select the com port.
  • Page 22 8) The Install New Modem window will update again. Click on Finish to proceed. 9) The Modems Properties window should appear. Click on the Properties button. SX4e CDMA 800 • SX4e CDMA 1900 Technical Manual...
  • Page 23 10) The Standard 19200 bps Modem Properties window will open in the General tab. Set as shown with the com port you have selected. 11) Then click on the Connection tab. Set as shown below. SX4e CDMA 800 • SX4e CDMA 1900 Technical Manual...
  • Page 24 12) Click on the Advanced button. Set as shown. 13) Click on OK and Close to back out of each window. Your modem is now set up. SX4e CDMA 800 • SX4e CDMA 1900 Technical Manual...

Table of Contents