ILA-0931 BEVERAGE-AIR SHEET 1 OF 3 ® REV. B INSTALLATION AND OPERATING INSTRUCTIONS Models: MT/RI/FC Installation Receiving Inspection: Upon receipt, check all packages and accessories or optional components including legs, casters, and shelves. Legs & Casters: (optional) (See Fig. 1) Legs screw directly into the base.
Page 3
ILA-0931 BEVERAGE-AIR SHEET 2 OF 3 ® REV. B Operation Electrical Supply and Connections: Plug all standard models into 115 volts A.C. 60 cycle outlet. Low line voltage is often the cause of service complaints. Check to see that the line voltage is 110 volts or more with the unit running.
REFRIGERATION SYSTEM SERVICE AND ANALYSIS CHART REFRIGERATION SYSTEM The Refrigeration System consists of a hermetically sealed compressor and finned evaporator and condenser. CONDENSER The condenser has wide finned spaces, which allow more air passage with less dirt or dust accumulation. The condenser still requires periodic cleaning for maximum efficiency.