UPFLOW/DOWNFLOW CASED EVAPORATOR COIL
Table of Contents
EVAPORATOR COIL SAFETY .......................................................1
INSTALLATION REQUIREMENTS ................................................1
Tools and Parts ............................................................................2
System Requirements ..................................................................2
Location Requirements ................................................................2
Drain Requirements......................................................................2

INSTALLATION INSTRUCTIONS ..................................................2

Inspect Shipment .........................................................................2
Install Upflow/Downflow Evaporator Coil ....................................2
Install Condensate Drains ............................................................3
Verify Orifice Size .........................................................................3
Connect Refrigerant Lines............................................................3
ASSISTANCE OR SERVICE ...........................................................4
Accessories ..................................................................................4
EVAPORATOR COIL SAFETY
Recognize this symbol as a safety precaution.
Recognize Safety Symbols, Words and Labels
The following symbols and labels are used throughout this
manual to indicate immediate or potential hazards. It is the
owner's responsibility to read and comply with all safety
information and instructions accompanying these symbols.
Failure to heed safety information increases the risk of serious
personal injury or death, property damage and/or product
damage.
WARNING
Hazards or unsafe practices could result in property
damage, product damage, severe personal injury or death.
CAUTION
Hazards or unsafe practices may result in property
damage, product damage, personal injury or death.
Whirlpool
®
Models: WCC
WPIO-284B
INSTALLATION INSTRUCTIONS
CAUTION
Hazards or unsafe practices may result in property
or product damage.
WARNING
Installation and repair of this unit should
be performed ONLY by individuals meeting
the requirements of an "Entry Level Technician"
as specified by the Air-Conditioning, Heating and
Refrigeration Institute (AHRI). Attempting to
install or repair this unit without such background may
result in product damage, personal injury or death.
WARNING
HIGH VOLTAGE!
Disconnect ALL power before servicing.
Multiple power sources may be present.
Failure to do so may cause property damage,
personal injury or death.
IMPORTANT: The United States Environmental Protection Agency
(EPA) has issued various regulations regarding the introduction and
disposal of refrigerants in this unit. Failure to follow these regulations
may harm the environment and can lead to the imposition of
substantial fines. These regulations may vary by jurisdiction. A
certified technician must perform the installation and service of this
product. Should questions arise, contact your local EPA office.
This product is designed and manufactured to permit installation
in accordance with national codes. It is the installer's
responsibility to install this unit in accordance with national codes
and/or prevailing local codes and regulations.
INSTALLATION REQUIREMENTS
These instructions are intended as a general guide only for use by
qualified persons and do not supersede any national or local
codes and regulations in any way. Compliance with all local,
state, or national codes and regulations pertaining to this type of
equipment should be determined prior to installation.
Read this entire instruction manual, as well as the instructions
supplied in separate equipment, before starting the installation.
All models are designed for indoor installation only.
Install the conditioned air plenum, ducts and air filters (not provided)
in accordance with NFPA 90B Standard for the Installation of Warm
Air Heating and Air-Conditioning Systems (latest edition).
Air filters (not provided) must be listed as Class 2 furnace air filters.

Advertisement

loading

Summary of Contents for Whirlpool WCC

  • Page 1: Installation Instructions

    Install the conditioned air plenum, ducts and air filters (not provided) in accordance with NFPA 90B Standard for the Installation of Warm Air Heating and Air-Conditioning Systems (latest edition). Air filters (not provided) must be listed as Class 2 furnace air filters. Whirlpool ® Models: WCC WPIO-284B...
  • Page 2: Location Requirements

    Tools and Parts Drain Requirements Gather the required tools and parts before starting installation. All vertical mount models come from the factory with right Read and follow the instructions provided with any tools listed and left front drain connections. here. Multiposition models come from the factory with right and left front drain connections for vertical installations and left front Tools Needed...
  • Page 3 Evaporator Coil Drain Pan Clearances A trap must be installed in the drain line below the bottom of the drain pan. If a copper drain line is used, solder a short piece of pipe to the connector before installing a drain fitting. NOTE: Do not over-torque the ³⁄₄"...
  • Page 4 Please include a daytime phone number in your correspondence. (45.7 cm) away from the braze joint. 10. Braze the suction line. Accessories To order accessories contact your Whirlpool ® Home Cooling and Heating dealer. ®Registered Trademark/TM Trademark of Whirlpool, U.S.A., WPIO-284B Manufactured under license by Tradewinds Distributing Company, LLC., Jacksonville, Florida...

This manual is also suitable for:

Upflow/downflow cased evaporator coil