Outdoor Unit Wiring Diagram; Power Supply - FUNAI 12D-2407 Service Manual

Table of Contents

Advertisement

Outdoor unit wiring diagram

THR
Contactor
Thermal Overload Relay
CON
RV
Outdoor Fan Motor
Four Way Valve Coll
FM2
Outdoor Fan Capacitor
Outdoor Fan Capacitor
FM3
Outdoor fan motor
3-Phase Direction Device
R-PH
L
R S T
2
L1 L2L3 N
F V C L N
CON
THR
CM

Power Supply

To Indoor Unit
To Indoor Unit
3N
400V 50Hz
Compressor
-7-