1. Description
The programming cassette allows you to program for the
weekdays Monday to Friday as well as for the weekend, i.e.
Saturday to Sunday, up to 4 different time block in each
case, during which the heater is switched on. The
programming cassette can be used individually, i.e. for one
heater, or serially, i.e. for a group of heaters (e.g. for a
complete dwelling unit).
In the case of serial use, one heater is fitted with the
programming cassette. This unit is the so-called "master
control". After the electrical wiring (as shown in the
installation instructions of the heater) has been completed,
all time functions set on the master device will be
transmitted to each slave heater connected in series. The
heating program preset on the master device (time blocks
for On/Off) will also be executed on all slave heaters.
2. Installation
Switch off heater. Using a
narrow bladed screwdriver,
release the cover. Insert the
programming cassette fully
into the opening. If
necessary, the cassette can
be secured against
unauthorised removal by
means of the screw
supplied.
3. Setting the Time and Day
Press the PROG button.
The "clock" symbol appears
in the upper left corner of
the display and the hours
flash. Set the hours using
the ▼▲ buttons, confirm
with ENTER. Use the same
procedure to set the
minutes. Confirm with
ENTER.
The weekday indicator ► flashes. Select the individual
weekdays using the ▼▲ buttons and confirm with ENTER.
M Monday
T Tuesday
F Friday
S Saturday
4. Manual Switching On/Off Mode
Switch on the heater (indicator lamp is illuminated).
Press the MODE button
until MAN ON appears on
the display. The device is
switched on. If you wish to
switch the device off, press
MODE once more. The
display MAN OFF appears.
The device is switched off.
M
T
W
00
:00
T
F
S
MAN
OFF
S
MODE PROG
ENTER
W Wednesday T Thursday
S Sunday
14
:00
MAN
ON
OFF
MODE PROG
ENTER
5. Automatic Mode
Switch on the heater. First, the weekdays Monday to Friday
are set. Press the PROG button twice. P1 ON appears on
the display and the hours flash. Set the hours using the ▼▲
buttons, confirm with ENTER. Use the same procedure to
set the minutes. Confirm with ENTER.
Note: Minutes can be set in 10-minute increments only!
P1 OFF now appears on the
display. Set the desired switch-off
time and confirm with ENTER.
Program P1 has thus been set. P2
now appears, i.e. another heater
operating time can be
programmed. Programs P3 and P4
can be set in the same manner.
After the P4 OFF display has been confirmed, the program
switches to the setting mode for the two weekend days
Saturday and Sunday. The procedure for setting these time
blocks is the same as for the weekdays. The arrow on the
right of the display marks the currently selected day.
To prematurely abort the setting procedure, press the
PROG button. All values already set will be retained.
For the preset programs to be executed, the programming
cassette must be in the AUTO (automatic) mode. The
operating mode can be selected by means of the MODE
button.
6. Key Lock Setting
Successively press ENTER and
MODE. The buttons must be
pressed within 1 second. The key
symbol appears on the display. All
key functions are locked.
When the key combination is
pressed once more, the keys are
unlocked.
7. ADVANCE Mode
The ADVANCE mode enables the
heater to provide instant heat, i.e.
before the preset starting time.
Example: It is 2 p.m. A heater
operating time from 5 p.m. – 7
p.m. has been programmed, but
you want to start the heater
operation immediately. The
programmer is in the AUTO mode.
Press the ▲ button for 3 seconds. ADVANCE appears on
the display. The heater is now switched on and operates
until the end of the programmed time period (i.e. until 7
p.m.). When the originally programmed starting time of the
heater
(5 p.m.) is reached, ADVANCE will disappear from the
display.
The ADVANCE function can be manually cleared at any
time. Simply press the ▼ button.
453321.67.98gb 02/06/A
M
T
ON
W
00
:00
T
P1
F
S
AUTO
S
MODE PROG
ENTER
M
T
W
14:00
T
F
S
S
MODE PROG
ENTER
ON
14
:00
ADVANCE
AUTO
MODE PROG
ENTER
M
T
W
T
F
S
S