Protection - K-Star TAC-09CHSA User Manual

Split wall-mounted air conditioner
Table of Contents

Advertisement

1 1

Protection

Operating condition
The protective device maybe trip and stop
the appliance in the cases listed below.
Outdoor air temperature is over 24c
HEATING
Outdoor air temperature is below -7c
o
(-15c for inverter models,it
Room temperature is over 27c
Outdoor air temperature is over
o
(or below 0c for inverter models)
COOLING
Room temperature is below 21c
Room temperature is below 18c
DRY
*
For Tropical (T3) Climate condition models, the
temperature point is 52
instead of 43 .
If the air conditioner runs in COOLING or DRY mode with
door or window opened for a long time when relative
humidity is above 80%,dew may drip down from the outlet.
Features of protector
The protective device will work as follows.
Restarting the unit at once after operation
stops or changing mode during operation, you
need to wait 3 minutes.
Connect to power supply and turn on
the unit at once, it may start 20 seconds
later.
If all operation has stopped, press ON/OFF
button again to restart.
Timer should be set again if it has been
canceled.
Preheat
At the beginning of HEATING operation, the airflow from indoor unit is discharged 2-5
minutes later.
Afterheat
After the finishing of HEATING operation, the airflow from indoor unit is discharged 2-5
minutes.
Defrost
In HEATING operation the appliance will defrost (de-ice) automatically to raise efficiency.
This procedure usually lasts 2-10 minutes. During defrosting, fans stop operation.
After defrosting completes, it returns to HEATING mode automatically.
Note: Heating is NOT available for cooling only air conditioner models.
Install the air conditioner at a place that
can bear its weight in order to operate
o
more quietly.
o
)
's optional
Install the outdoor unit at a place where
the air discharged and the operation noise
o
would not annoy your neighbors.
*
o
43c
Do not place any obstacles in front of the
air outlet of the outdoor unit lest it increases
o
the noise level.
o
After using for long time, the air conditioner
should be inspected on the following items.
Overheat of the power supply cord and plug
or even a burned smell.
Abnormal operating sound or vibration.
Water leakage from indoor unit.
Metal cabinet electrified.
Stop the air conditioner if above trouble occurs.
It is advisable to have a detail inspection after
using it for 5 years even if none above occurs.
Features of HEATING mode
Noise pollution
Inspection
10