Alexor PC9155-433/868 Installation Manual page 37

2-way wireless security suite, series 2-way wireless keypad
Table of Contents

Advertisement

* Attributes for Option 9 & 10
09 S y s t em Trouble
10 S y s t em E v ent
S ec t
P GM
P GM Ty pe
[ 501]
1
[ 502]
2
[ 591-592] Inac t iv it y Timers 1 & 2 S t art and E nd Times
S ec t
N A
[ 591]
Timer #1
9999
[ 591]
Timer #2
9999
[ 600] 2-Way A udio Cont rol Opt ions
O pt
O N
N A C P EU
1
Tampers Enabled
2
Openings & Closings Enabled
3
[A] Key Alarm Enabled
4
[P] Key Alarm Enabled
5
Duress Alarm Enabled
6
Opening After Alarm Enabled
7
Siren Active During 2-Way Audio
8
For Future Use
[ 609] Module Tamper Report ing Codes
Keypad 1 Tamper
Keypad 2 Tamper
Keypad 3 Tamper
Keypad 4 Tamper
Keypad 1 Tamper Restore
Keypad 2 Tamper Restore
Keypad 3 Tamper Restore
Keypad 4 Tamper Restore
[ 610] A lt ernat e Communic at or Rec eiv er Trouble Report ing Codes
Receiver 1 Trouble
Receiver 2 Trouble
Receiver 3 Trouble
Receiver 4 Trouble
General Alternate Communicator Trouble
[ 700] A ut omat ic Cloc k A djus t
N A
60
C P
60
EU
Attri b u te :
1
Service Req
ON
Event
OFF
Disabled
Disabled
Attri b u te :
1
ON
Burg Event
OFF
Disabled
Disabled
1
S t art Time
C P
EU
9999
9999
9999
9999
Valid entries are (00-99) seconds
60
2
3
4
AC Fail
TLM Fault
FTC
Disabled
Disabled
2
3
4
Fire
Panic
Medical
Event
Event
Event
Disabled
Disabled
2
3
4
N A
C P
EU
9999
9999
9999
9999
9999
9999
O F F
Tampers Disabled
Openings & Closings Disabled
[A] Key Alarm Disabled
[P] Key Alarm Disabled
Duress Alarm Disabled
Opening After Alarm Disabled
Siren Silent During 2-Way Audio
Siren 1 Tamper
Siren 2 Tamper
Siren 3 Tamper
Siren 4 Tamper
Siren 1 Tamper Restore
Siren 2 Tamper Restore
Siren 3 Tamper Restore
Siren 4 Tamper Restore
Receiver 1 Trouble Restore
Receiver 2 Trouble Restore
Receiver 3 Trouble Restore
Receiver 4 Trouble Restore
General Alternate Communicator Trouble Restore
5-13
5 Installer Programming
5
6
7
Device
Device
Device Fault
Tamper
Low
Disabled
Disabled
Disabled
5
6
7
Supervisory
Priority
Duress
Event
Event
Event
Disabled
Disabled
Disabled
5
6
7
E nd Time
Valid times are
00:00 - 23:59 Hrs
9999 to disable
8
Loss of
Clock
Disabled
8
Follows
Timer
Latched
8

Hide quick links: