[ 101] -[ 134] Zone A t t ribut es (A t t ribut es 10-13 are res erv ed f or Fut ure Us e)
Attri b u te :
Zo n e Typ e
00 Null Zone
01 Delay 1
02 Delay 2
03 Instant
04 Interior
05 Interior Stay/Away
06 Delay Stay/Away
07 Future Use
08 Future Use
09 24-Hour Supervisory (Hardwired)
10 24-Hour Supervisory Buzzer
11 24-Hour Burglary
12 Future Use
13 24-Hour Gas
14 Future Use
15 24-Hour Medical
16 24-Hour Panic
17 24-Hour Emergency
18 Future Use
19 24-Hour Water
20 24-Hour Freeze
21 Future Use
22 Momentary Keyswitch Arm
23 Maintained Keyswitch Arm
24 Future Use
25 Interior Delay
26 24-Hour Non-Alarm (local alarm)
27 Future Use
28 Future Use
29 Future Use
30 Future Use
31 Day Zone
32 Instant Stay/Away
33 Future Use
34 Future Use
35 Future Use
36 24-Hr Non-Latching Tamper
37 Night Zone
81 24-Hr Carbon Monoxide (Wireless)
82 Audio Verification Monitor
87 Delay 24-Hr Fire (Wireless)
88 Standard 24-Hr Fire (Wireless)
89 Auto Verified Fire (Wireless)
i
* F or UL ins tallations : do not c hange attr ibute 5 ( F or c e Ar ming) fr om the default s etting.
i
F or CP- 01 ins tallations :
O ption 6 ( Swinger ) is defaulted O N for z one definitions 09- 11, 13- 17, 19, 20
O ption 7 ( T X Delay ) is defaulted O N for z one definitions 01- 06, 09- 11, 13- 17, 19, 20, 25, 32, 36,
1
2
3
= ON
Audible Steady
Chime
Bypass
OFF
Silent
Pulsed
No
5-5
4
5
6
7
Force
Swing
TX Dly
X-Zone
No
No
No
No
No
5 Installer Programming
8
9
14
15
16
2-way
NC
SEOL
DEOL
Audio
Loops
Need help?