RF Technology Eclipse Series Operation, Maintenance And Installation Manual page 7

Hot standby switch
Table of Contents

Advertisement

5
Check the HSS GREEN PWR LED is lit ON.
6
Press the RESET push button switch on the rear of the HSS to switch it to
MAIN repeater. The RED ALM LED should be OFF and the main repeater is
functioning properly. This is the normal operation mode.
7
Test the STANDBY mode by introducing an alarm in the main repeater. If an
ATI is fitted simply pull out the receiver or transmitter sufficiently to
disconnect it from the rack frame connector and an alarm will occur. The HSS
should switch to STANDBY and the RED ALM LED should light ON.
8
If JP1 and JP2 are set correctly the HSS will introduce a double beep audio
tone mixed with the standby transmitter audio. This is the STANDBY mode.
9
To RESET the HSS, restore the main repeater to normal operation (no alarms)
before pressing the RESET push button switch.
10
This ends the installation but the remote RESET (FORCE_MAIN) and remote
FORCE_STANDBY can be tested in a similar way.