Download Print this page
United Security Products AVD-45b Installation And Instruction Manual

United Security Products AVD-45b Installation And Instruction Manual

Automatic voice dialer
Hide thumbs Also See for AVD-45b:

Advertisement

Quick Links

United Security Products
Model AVD-45b
Automatic Voice Dialer
Patents
Pending
Installation and Instruction Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the AVD-45b and is the answer not in the manual?

Questions and answers

Summary of Contents for United Security Products AVD-45b

  • Page 1 United Security Products Model AVD-45b Automatic Voice Dialer Patents Pending Installation and Instruction Manual...
  • Page 2 16 seconds. This manual describes how to set up, install and operate the AVD-45b. Please read the entire booklet before operating the dialer. For specific questions or problems, contact a USP Technical Service Representative at (858) 597-6677, Monday –...
  • Page 3: Rear View

    AVD-45b PANEL DISPLAY BLACK YELLOW STANDBY BATTERY WHITE TEL LINE ALARM REAR VIEW Keypad Speaker Mode Program/ Pause AVD-45b 9V ALKALINE Automatic Voice Dialer BATTERY BACK VIEW FRONT VIEW - 3 -...
  • Page 4 N.C./N.O. DRY CONTACT ACTIVATION HOOKUP PANEL OR SENSOR PP-1 NC, NO, MOMENTARY, OR CONTINUOUS ALARM STANDBY ACTIVATION BATTERY (optional) 12VDC ALARM BLACK YELLOW WHITE TEL LINE GREEN Notes: 1. In momentary mode the dialer automatically dials all numbers even after the alarm input is restored to non-alarm. To stop dialing you must press the M button to switch the unit to the OFF mode.
  • Page 5 VOLTAGE LEVEL ACTIVATION HOOKUP WHEN THE ALARM OUTPUT VOLTAGE IS RELAY DRIVEN, YOU MUST ADD A 1K RESISTOR ACROSS ALARM OUTPUT TERMINALS. HOOK UP DIALER AS SHOWN BELOW. Note: You may either program for momentary or ALARM CONTROL PANEL PP-1 W/VOLTAGE TRIGGER continuous voltage activation.
  • Page 6: Programming The Dialer

    Model AVD-45b stores and dials up to 4 telephone numbers and/or pager numbers. Each number may contain up to 28 digits, including a maximum of 10 “pause” segments (a pause is 2 seconds long and counts as a digit) and an optional “pound”...
  • Page 7 The AVD-45b will call up to 4 numbers. This can be any combination of regular telephones, cellular telephones or pagers. The 4 numbers being called will be stored in locations 1-4. Any of locations 1-4 can store up to 28 digits and dial a telephone or pager.
  • Page 8 PROGRAMMING THE DIALER Example 1: Store telephone number 1-800-555-1212 in Location 1. Program/Pause Press: (Press momentarily) Example 2: Store telephone number 555-1212 in Location 2. Program/Pause Press: (Press momentarily) Follow the steps above to store the desired numbers in Memory Locations 3 and 4. Note: If you enter the wrong number or wish to change a programmed number, press the MODE (“M”) button until “PROGRAM: NUMBERS”...
  • Page 9 8. You may store pager number and numeric code in any memory location (1-4). 9. When testing the pager operation, it is recommended that the AVD-45b be in the “OPERATE” mode, connected to a phone line and the input triggered.
  • Page 10 PROGRAMMING THE DIALER Example 1: Store pager number 555-1212 and numeric message 911 in Location 1. Program/Pause Program/Pause Press: (Hold for 2 seconds) (Press momentarily) Example 2: Store pager number 1-800-555-1212 with access code 3 and numeric message 911 in Location 2. Program/Pause Press: (Hold for 2 seconds)
  • Page 11 2. Press “1” (YES) at the “PROGRAM: CHANNEL” prompt. 3. Press “1” (ON) for a 60 second Exit delay (This provides a 60 second exit delay, after the AVD-45b is set in the “OPERATE” mode, before the unit will react to a sensor trip, allowing time to exit).
  • Page 12 1. Press the “M” key until “PROGRAM: NUMBERS” appears in the LCD, then press “2” twice. 2. Press “1” at the “PROGRAM: OGM” prompt. 3. Locate the microphone on the lower left corner of the AVD-45b. For best results when recording, speak about 12 inches from the microphone in a clear and normal voice.
  • Page 13 5. Make sure the sensor is in a non-alarm condition. 6. Press “M” until “OPERATE” appears in the LCD. 7. Trigger the sensor to simulate an alarm condition. If there are any delays programmed, the AVD-45b will wait until they elapse before activating and dialing.
  • Page 14 8. The AVD-45b will sequentially dial the programmed Locations (1-4). If there is no number stored in a location, it will be skipped. The OGM will be delivered when the AVD-45b receives an answer. (The OGM will not be played through the speaker.) For pager numbers, the pager code will be transmitted instead of an OGM.
  • Page 15 IMPORTANT INFORMATION LOCATION Place the dialer on a flat level surface or mount the unit on the wall, away from extreme cold or heat, direct sunlight, excessive humidity and away from equipment that generates a strong magnetic field. Avoid placing near large metal objects and areas that produce smoke, dust or mechanical vibrations. CARE Clean the housing with a soft cloth lightly moistened with water or mild detergent solution.
  • Page 16 ?? Connect the equipment into a different outlet so that the equipment and receiver are on different branch circuits. ?? Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by United Security Products, Inc. will void the warranty. - 16 -...
  • Page 17 FEATURES SUMMARIZED ??Non volatile (EEPROM) memory for voice message and phone numbers ??Calls up to 4 phone numbers, any combination of telephones or pagers ??Sends up to 16 second voice message to telephones or numeric code to pagers ??Record your own message in any language ??Easily change message and phone numbers without a programmer ??Voice chip technology (no tape required) ??Ability to program up to 10 (2-second) pauses and pound (#) for pager dialing...
  • Page 18: Dialer Accessories

    DIALER ACCESSORIES Consult factory for availability and pricing 24V APPLICATION: AVD-45b/F - For this option the dialer is configured to operate at 24VDC to 32VDC max. All other specifications apply. - AC-2 AC/DC ADAPTOR (500mA) Plugs into regular 110VAC outlet to provide the dialer with the required 12VDC primary power.