Technical Data - Baxi Potterton Combi 24 HE Installation & Service Instructions Manual

Wall mounted powered flue condensing combination boiler gas fired central heating unit
Hide thumbs Also See for Combi 24 HE:
Table of Contents

Advertisement

Heat
Output CH (Non-Condensing)
Max
Min
kW
24
9.8
Heat Output
CH (Condensing)
Max
Min
kW
25.2
10.1
Heat Input DHW
Max
kW
24.8
Heat Output DHW
Max
kW
24
Max Gas Rate (Natural Gas - G20)
(After 10 mins)
m3/h
2.62
Burner Pressure (Natural
Gas - G20)
Max Rate
Min Rate
mbar
10.2 :t 0.5
2 :t 0.2
Inlet Pressure (Natural Gas - G20)
mbar
20
Burner Injector (Natural Gas - G20)
15 x 1.18mm Diameter
Electrical Supply
230V- 50Hz
(Appliance must be connected to an
earthed supply)
Power
Consumption
170W
External
Fuse Rating
3A
Internal Fuse Rating
Fuse 2A Fast Blow to BS 4265
4.0
Electrical
Protection
IPX4D
NOx Class
3
Condensate Drain
1" BSP
Flue Terminal
Dimensions
Diameter
Projection
100mm
125mm
Connections
Gas Supply
Central Heating Flow
Central Heating Return
Cold Water Mains Inlet
DHW Flow
Pressure Relief Discharge -
copper tails
22mm
22mm
22mm
15mm
15mm
15mm
Outercase Dimensions
Casing Height
Overall Height Inc Flue
Elbow
Casing Width
Casing Depth
780mm
965mm
450mm
345mm
Clearances
Above Casing
Below Casing
Front
Front
L.H. Side
R.H. Side
200 mm Min
200 mm Min
450 mm Min (For Servicing)
5 mm Min (In Operation)
5 mm Min
5 mm Min (In Operation)
20 mm Min (See Note*)
*NOTE:
The boiler can be operated with a
clearance of 5mm at the right. This is also
sufficient for routine maintenance.
However a clearance of 20mm is required
if it is necessary to remove the secondary
heat exchanger. This should be
considered when siting the appliance and
in the event of any subsequent alterations
in the area of installation
Weights
Packaged Boiler Carton
Installation Lift Weight
kg
50
43.5
5
4.5
4
3.5
3
E
2.5
~
2
::;
1.5
0.5
0
0
200
TECHNICAL
DATA
Central
Heating Primary
Circuit
Pressures
Pump
Available Head
See graph below
Expansion
Vessel
-
(For Central Heating
only. Integral with appliance)
bar
Min Pre-charge Pressure
0.5
litre
Max Capacity of
CH System
Primary Water Content
of Boiler (unpressurised)
125
1.0
Temperatures
C.H. Flow Temp (adjustable)
35°C to 85°C max(:t 5°C)
D.HW.
Flow Temp
35°C to 65°C max(:t 5°C)
dependent upon flow rate
Pump
- Available Head
400
600
800
1000
1200
Flow Rate
(I/h)
Appliance Type
C12
C32
Appliance Category
CAT II 2H 3P
Heat Input CH
Max
Min
kW
24.8
10.6
LPG Propane - G31
Burner Injector 15 x O.77mm diameter
Burner Pressure
Max Rate IMin Rate
Propane
mbar 21.8 :t 0.514.4 :t 0.2
Inlet Pressures
mbar
37
bar
Safety Discharge
3
Max Operating
2.5
Min Operating
0.5
Recommend Operating
1-2
DHW Circuit
bar
Pressures
Max Operating
8
Min Operating
0.2
Min Operating Pressure
at 11.1 I/min
0.9
Flow Rates
I/min
DHW Flow Rate
@ 30°C Rise
11.5
DHW Flow Rate
@ 35°C Rise
9.8
Min Working
DHW Flow Rate
2.5