Yearly Maintenance (Or Every Two Tons); Clean The Exhaust Duct - Lopi Pioneer User Instructions

Lopi pioneer (heritage bay ps) pellet stove
Hide thumbs Also See for Pioneer:
Table of Contents

Advertisement

2 8

Yearly Maintenance (or every two tons)

WARNING:
Disconnect the power cord prior to conducting service.
The following section details extensive maintenance procedures. We strongly suggest these items
be carried out by a trained service technician, possibly by a service agreement set up with your dealer.
Soot and Flyash: Formation and Need for Removal Ð The products of combustion will
contain small particles of flyash. The flyash will collect in the exhaust venting system and restrict the
flow of the flue gases. Incomplete combustion, such as occurs during startup, shutdown, or incorrect
operation of the room heater will lead to some soot formation which will collect in the exhaust venting
system. The exhaust venting system should be inspected at least once every year to determine if
cleaning is necessary.
Clean the Vertical Exhaust Duct

Clean the Exhaust Duct

Travis Industries
Maintenance
(the stove must be cool and unplugged)
Remove both
refractory side clips.
Clean this area
behind where the
refractory rests
(both sides).
(the stove must be cool and unplugged)
a
Open the hopper lid and remove the two
screws holding the side doors in place.
Phillips
Screwdriver
Cover
Plate
9 3 5 0 8 0 5 0
Remove the
refractory.
Remove these doors to
remove fallen flyash and
soot (see ÒBi-Weekly
Maintenance for detailsÓ)
Swing the side
b
panels open.
Use a vacuum or
bottle brush to
remove all flyash
from the exhaust
duct.
Remove the cover
c
plates over the exhaust
duct (both sides)
d
2 9 0 9 0 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents