Suburban SF-20 Installation Instructions Manual page 8

Table of Contents

Advertisement

ELECTRICAL
CONNECTION
GAS
CONNECTION
OUTER PANEL WITH SCREWS
FLASHLIGHT
TIE-DOWN SCREW
(FURNACE TO CABINET)
OUTSIDE SKIN
CAULK ALONG THE EDGE OF THE CUTOUT
(ALL THE WAY AROUND)
SECURE FRAME TO
(16 PLACES)
Figure 4
ELECTRODE
LIGHT BEAM
Figure 5
8
ANCHOR FURNACE CABINET TO COACH
FLOOR (2) PLACES AS ILLUSTRATED
BACK OF CABINET MUST BUTT
AGAINST THIS EDGE OF THE FRAME
DOOR FRAME
CAULK BEHIND VENT CAP AS SHOWN TO SEAL
BETWEEN EXHAUST AND INTAKE AND TO PREVENT
MOISTURE INSIDE FURNACE COMPARTMENT. APPLY
CAULKING GENEROUSLY AROUND PERIMETER OF
VENT CAP AND ACROSS CENTER AS SHOWN. CENTER
PUTTY STRIP IS ESSENTIAL.
4 SCREWS
DOOR MOUNTING
VENT CAP & EXHAUST TUBE
FURNACE ACCESS DOOR
MARKED CENTERLINE OF LANCE
TOP OF BURNER
FRONT END OF BURNER
MARK BURNER .187 FROM BACK OF LANCE
.125 SPARK GAP OVER TOP OF BURNER
SIDE OF BURNER
LANCE
VENTURI TUBE
AIR INTAKE TUBE
WITH GASKET
6 SCREWS
(SUPPLIED)