4 Operation
4.5.1
Setting the maximum radiator temperature
control
2
1
Fig. 4.6 Setting the maximum radiator temperature
control
When you adjust the temperature, the set value is
shown in the display (2). After five seconds the display
returns to standard mode (the current heating flow
temperature).
Normally you can adjust the knob (1) continuously
up to a flow temperature of 75 °C. However, higher
temperatures can be set on your appliance, have your
engineer make adjustments so that you can operate the
heating system at higher flow temperatures.
4.5.2
Setting a room or outside temperature
controller
1
Fig. 4.7 Setting a room or outside temperature
controller
• Set the room thermostat (1) and/or the thermostatic
radiator valves (2) according to the instructions
supplied with the control(s).
8
Supplied by HeatingSpares247.com
2
Note!
Vaillant offer room thermostat/time control
accessories which give accurate and economic
room temperature control as well as improved
comfort.
The boiler will now operate automatically to provide
central heating for the conditions selected on the
external controls.
After the boiler stops operating the pump will continue
to operate for a short period to fully disperse the heat
from the boiler.
After a power cut or every 23 hour in frost setting
/summer mode the pump will run for one minute to
prevent it from sticking. This will also occur during
normal operating if there is no demand for more than
24 hours.
4.6
Pump exercise
Note!
The boiler incorporates an anti-cycling
economiser control to prevent energy wasteful
on and off operation of the boiler for short
periods when in the central heating mode.
When turning the room thermostat to a higher
setting there may be a short delay before the
boiler operates.
4.7

Status displays

2
Fig. 4.8 Status displays
The status displays provide information on the
operating
status of the appliance.
• Press the "i" button (1) to activate the status
displays.
The display (2) then shows the current status code,
for example "S. 4" for burner operation. The table
below explains the most important status codes.
In switching phases, for example on starting up
again after the flame was extinguished, the status
message "S." briefly appears.
• Press the "i" button (1) again to switch the display
back to normal mode.
1