Selection Of Installation Positions For Outdoor Unit - Pridiom AWS090HR Installation Manual

High wall split air conditioner
Hide thumbs Also See for AWS090HR:
Table of Contents

Advertisement

INSTALLATION & REPAIR GUIDE
Split Wall-Mounted air conditioner

*Selection of installation positions for outdoor unit*

* To install the outdoor unit at the places which can stand the load of the machine weight and will
not cause big vibrations and noises;
* To install the unit at the places not to be exposed to rain or direct sunshine, and the places with
good ventilation;
* The noises generated from the unit will not affect the neighboring places;
* Do not install the unit on non-metal frame;
* Not to install the unit at the places where there might occur the generation, inflow, stay or
leakage of inflammable gases;
* Pay attention to the drainage of the condensed water from the base plate during operations;
* To avoid the air outlet being directly against the wind.
Detailed space requirements around the outdoor unit
1. When there are obstacles above
the unit
4. When there are obstacles at the front and rear sides.
2. When the front (air outlet) is open
100mm(4") min
200mm(8") min
200mm(8") min
300mm(1') min
100mm(4") min
1000mm(3'4") min
2
3. When there are obstacles only in
the front (air outlet)
Space for maintenance
Shown as in the following figure. Keep
the maintenance space in front of the
unit.
200mm
(8")min
500mm
Space for maintenance
(1'8")min
5. When there are obstacles all around
the unit on four sides.
Although the top side is open, the
installation is not to be done if there
are obstacles all around.
* At least two sides should
be kept open.

Advertisement

Table of Contents
loading

Table of Contents