Breckwell SP8500 Owner's Manual
Breckwell SP8500 Owner's Manual

Breckwell SP8500 Owner's Manual

Multi-fuel furnace
Hide thumbs Also See for SP8500:

Advertisement

UNITED STATES STOVE COMPANY
TESTED &
LISTED BY
OREGON, USA
Report #: 215-S-22b-2
Ì
Please read this entire manual before installation and use of this appliance. Failure to follow
these instructions could result in property damage, bodily injury, or even death.
Ì
&RQWDFW \RXU ORFDO EXLOGLQJ RU ¿UH RI¿FLDOV DERXW UHVWULFWLRQV DQG LQVWDOODWLRQ LQVSHFWLRQ
requirements in your area.
Ì
SAVE THESE INSTRUCTIONS.
French version is available for download from the U. S. Stove website: http://www.Breckwell.com/
81,7(' 67$7(6 6729( &203$1< ‡  ,1'8675,$/ 3$5. 52$' ‡ 6287+ 3,776%85* 7(11(66((  ‡ :::866729(&20
USSC
"Keeping North America Warm Since 1869"
BRECKWELL
Exceptional Heat, Outstanding Value
MULTI-FUEL FURNACE MODEL SP8500
PORTLAND,
Owner's Manual
FOR TECHNICAL ASSISTANCE:
PHONE: (800) 750-2723
FAX: (423) 837-2109
®
Approved for
US and Canadian use.
Safety tested and listed to UL
391-2010, ASTM E1509-04,
and CSA-B366.1-11
CHUWL¿HG IRU LQVWDOODWLRQ LQ D
residential or mobile home as a
stand-alone or add-on furnace
(ductwork connection only).
Part No.: 852014
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SP8500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Breckwell SP8500

  • Page 1 Ì SAVE THESE INSTRUCTIONS. French version is available for download from the U. S. Stove website: http://www.Breckwell.com/ 81,7(' 67$7(6 6729( &203$1< ‡  ,1'8675,$/ 3$5. 52$' ‡ 6287+ 3,776%85* 7(11(66((  ‡ :::866729(&20 FOR TECHNICAL ASSISTANCE:...
  • Page 2: Table Of Contents

    Table of Contents TABLE OF CONTENTS ....................2 SAFETY PRECAUTIONS ................... 3 SPECIFICATIONS ....................... 4 +HDWLQJ 6SHFL¿FDWLRQV ..................4 Dimensions ...................... 4 (OHFWULFDO 6SHFL¿FDWLRQV ................... 4 Safety and EPA Compliance ................4 Fuel Considerations ..................5 INSTALLATION ......................5 Installation Options ..................6 Floor Protection ....................
  • Page 3: Safety Precautions

    Safety Precautions Ì IMPORTANT: Read this entire manual before installing Ì Disconnect the power cord before performing any and operating this product. Failure to do so may maintenance! NOTE: Turning the ON/OFF Switch to result in property damage, bodily injury, or even death. ”OFF”...
  • Page 4: Specifications

    1150 (max. approx.) SAFETY AND EPA COMPLIANCE Your Breckwell Furnace has been safety tested and listed to UL 391-2010, ASTM E1509-04, and CSA-B366.1-11, by OMNI-Test Laboratories, Inc. Portland, Oregon USA. It is also exempt from EPA Phase II requirements. USSC...
  • Page 5: Fuel Considerations

    Low ash content pellets will allow you to burn the furnace longer between cleanings. Only wood pellets manufactured to the Pellet Fuel Industries (P.F.I.) standard for residential pellet fuels are recom- mended. Performance will suffer if nonstandard pellets are used. Consult your local Breckwell reseller for more information on approved wood pellet fuel.
  • Page 6: Installation

    Installation INSTALLATION OPTIONS Ì Read this entire manual before you install and use your Multi-Fuel Furnace. Failure to follow instructions may result in property damage, bodily injury, or even death! 6HH VSHFL¿F LQVWDOODWLRQ GHWDLOV IRU FOHDUDQFHV DQG RWKHU LQVWDOODWLRQ UHTXLUHPHQWV &HUWL¿HG IRU LQVWDOODWLRQ LQ D 5HVLGHQWDLO 7\SH KRPH LQ WKH 86$ DQG &DQDGD $OVR PD\ EH LQVWDOOHG LQWR D 0DQXIDFWXUHG or Mobile Home.
  • Page 7: Clearances

    Installation CLEARANCES NOTE: Distance on the left-hand side of your Multi-Fuel Furnace LV VHW DW  LQFKHV IRU VXLWDEOH DFFHVV WR WKH FRQWURO SDQHO DQG IRU IXHO ORDGLQJ 7KLV GLVWDQFH PD\ EH OHVV EXW QRW OHVV WKDQ  LQFKHV USSC...
  • Page 8: Venting Requirements

    Installation VENTING REQUIREMENTS Ì ,QVWDOO YHQW DW FOHDUDQFHV VSHFL¿HG E\ WKH YHQW PDQXIDFWXUHU Ì Do not connect the pellet vent to a vent serving any other appliance or furnace. Ì 'R QRW LQVWDOO D ÀXH GDPSHU LQ WKH H[KDXVW YHQWLQJ V\VWHP RI WKLV XQLW Ì...
  • Page 9: Vent Termination Clearances

    Installation VENT TERMINATION CLEARANCES: Minimum 4-foot (1.22m) clearance below or beside any door or window that opens. Minimum 1-foot (0.3m) clearance above any door or window that opens. Minimum 3-foot (0.91m) clearance from any adjacent building. Minimum 7-foot (2.13m) clearance from any grade when adjacent to public walkways. Minimum 2-foot (0.61m) clearance above any grass, plants, or other combustible materials.
  • Page 10: Through The Wall Installation

    Installation THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION) To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the exhaust adapter is at least 24-inches above ground level, a straight section of pellet vent pipe can be used through the wall. Your furnace dealer should be able to provide you with an installation kit, which will include a wall thimble that will allow the proper clearance through a combustible wall.
  • Page 11: Primary And Secondary Furnace Illustrations

    Installation PRIMARY FURNACE This appliance requires the installation of a cold air return duct system. The return air will provide a better distribution RI ZDUP DLU WKURXJKRXW \RXU KRPH PDNLQJ WKH XQLW PXFK PRUH HI¿FLHQW WKDQ LI LQVWDOOHG ZLWKRXW D UHWXUQ V\VWHP This appliance must be installed by experienced personnel and in accor- dance with the instructions of the man-...
  • Page 12: How Your Furnace Works

    Component Location CLEANOUT TOOL ASH CLEANOUTS STAINLESS STEEL BAFFLE EXHAUST CLEANOUT (located behind the ash pan) USSC...
  • Page 13: Operation

    Operation CONTROL PANEL Turning the furnace OFF/ON, as well as adjustments for the fuel feed rate and room fan speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower left-hand side of your furnace.
  • Page 14: Unit Preparation

    LIGHTING INSTRUCTIONS CAUTION: DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE +27 :+,/( ,1 23(5$7,21 .((3 &+,/'5(1 &/27+,1* $1' )851,785( $:$< &217$&7 0$< &$86( 6.,1 %8516 %HIRUH OLJKWLQJ \RXU KHDWHU IRU WKH ¿UVW WLPH PDNH VXUH WKDW DOO LWHPV DUH RXW RI WKH KRSSHU DVK SDQ DQG ¿UHER[ area.
  • Page 15: Daily Operation

    Operation DAILY OPERATION Ì The hopper and furnace top will be hot during operation; therefore, you should always use some type of hand protection when refueling your furnace. Ì Never place your hand near the auger while the furnace is in operation. In the event of a power outage, the furnace WILL NOT function.
  • Page 16: Interior Chambers

    Maintenance INTERIOR CHAMBERS Open the Ash Cleanouts and scrap all ash into the ash pan. Open the damper and allow the ashes to fall into the ash pan. The damper may need to be slid in and out several times to clear any ash build-up. This may need to be done daily depending on fuel consumption.
  • Page 17: Repair Parts Diagram & List

    Parts Diagram USSC...
  • Page 18 Parts List Part No. Part No. Description Description Qty. Qty. Part No. Part No. Description Description Qty. Qty. 23786 Door Latch (C000022) 891331 Spring Handle-Brushed Nickel 24179 Feed Door Handle 891364 Hearth Plate 25427 Retainer, Agitator Motor 891374 Access Panel, Plenum 40501 Agitator, Cast 891423...
  • Page 19: Wiring Diagram

    Wiring Diagram Amendment USSC...
  • Page 20: Trouble Shooting

    Trouble Shooting Ì Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical components of the furnace. Ì Never try to repair or replace any part of the furnace unless instructions for doing so are given in this manual. All other work should be done by a trained technician.
  • Page 21: Error Codes

    Error Codes Below is a chart describing the Error Codes that might be displayed if an error occurs with your furnace. Error Error Possible Code Description Causes Err1 The high limit temperature sensor ‡ ,QDGHTXDWH YHQWLODWLRQ has tripped. ‡ 5RRP IDQ IDLOXUH ‡...
  • Page 22: Notes

    HOW TO ORDER REPAIR PARTS THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM YOUR BRECKWELL UNIT, AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER.
  • Page 23 WARRANTY INFORMATION CARD Name__________________________________________ Telephone #: (_____)_____________ City____________________________________________ State_______ Zip_________________ Email Address __________________________________________________________________ Model # of Unit________________________________ Serial #___________________________ Fuel Type: ‰Wood ‰Coal ‰Pellet ‰Gas ‰Other _________________________ Place of Purchase (Retailer)______________________________________________________ City____________________________________________ State_______ Zip_________________ If internet purchase, please list website address___________________________________ Date of Purchase _______________________________________________________________ ‰Alternative Heat ‰Main Heat Source...
  • Page 24 ° ¯ Fold Here Fold Here Fold Here PLACE STAMP HERE United States Stove Company P.O. Box 151 South Pittsburg, TN 37380 USSC...

Table of Contents