7.2.

When Replacing the Main PCB

After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at "software download" on the "Support Information from NWBG/VDBG-PAVC" web-site in
"TSN system", together with Maintenance software.
7.3.

Service Position

This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
No.
Parts No.
1
RFKZ0416
2
RFKZ0477
3
VFK1974
4
VFK1480
5
VFK1951
6
VFK1974
7
RFKZ0418
CAUTION-1. (When servicing FLASH TOP PCB)
1. Be sure to discharge the capacitor on FLASH TOP PCB.
Refer to "HOW TO DISCHARGE THE CAPACITOR ON FLASH TOP PCB".
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP PCB.
Table S1 Extension Cable List
Connection
FP9001 (MAIN) - CCD UNIT
FP9002 (MAIN) - LENS UNIT
FP9006 (MAIN) - LCD UNIT
FP9007 (MAIN) -REAR OPERATION UNIT
FP9003 (MAIN) - LCD UNIT
FP9004 (MAIN) - LCD UNIT
PP9002 (MAIN) - PS8001 (FLASH TOP)
19
Form
41PIN 0.3 FFC
45PIN 0.3 FFC
4PIN 0.5 FFC
6PIN 0.5 FFC
39PIN 0.3 FFC
4PIN 0.5 FFC
30PIN B to B