Kenwood TK-868G Service Manual page 33

Uhf fm transceiver
Hide thumbs Also See for TK-868G:
Table of Contents

Advertisement

TK-868G
Item
Condition
8. MIC
1) Set test mode
seisitivity
CH : CH1 - Sig1
check
AG : 1kHz/5mV
PTT : ON
Adjust [ *** ]
9. QT deviation 1) Set test mode
• Wide
Select "FQT" in tuning mode.
"_.FQT"
Deviation meter filter
LPF : 3kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
2) "_.F.Q.T"
PTT : ON
Adjust [ *** ]
3) "_.F.Q.T._."
PTT : ON
Adjust [ *** ]
• Narrow
4) "FQT *** ."
PTT : ON
Adjust [ *** ]
10. DQT
1) Set test mode
deviation
Select "FDQT" in tuning mode.
• Wide
"F.DQT"
Deviation meter filter
LPF : 3kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
2) "F.D.Q.T"
PTT : ON
Adjust [ *** ]
3) "F.D.Q.T._."
PTT : ON
Adjust [ *** ]
• Narrow
4) "FDQT *** ."
PTT : ON
Adjust [ *** ]
11. DTMF
1) Set test mode
deviation
Select "DTMF" in tuning mode.
• Wide
Deviation meter filter
LPF : 15kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
• Narrow
2) "DTMF *** ."
PTT : ON
Adjust [ *** ]
12. TONE
1) Set test mode
deviation
Select "TONE" in tuning mode.
• Wide
Deviation meter filter
LPF : 15kHz, HPF : OFF
PTT : ON
Adjust [ *** ]
• Narrow
2) "TONE *** ."
PTT : ON
Adjust [ *** ]
32
28
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Power meter Rear
ANT
Deviation
panel
meter
Oscilloscope
AF VTVM Front
MIC
AG
panel
Front
panel
Front
panel
Front
panel
Front
panel
Adjustment
Parts
Method
± 2.4kHz~3.4kHz
Check
± 50Hz (Wide/Narrow)
CH /
0.75kHz
0.35kHz
± 50Hz
CH /
0.75kHz
± 40Hz
0.36kHz
± 0.2kHz
CH /
3.0kHz
± 0.1kHz
1.5kHz
± 0.1kHz (Wide/Narrow)
CH /
3.0kHz
1.5kHz
Specifications/Remarks