NOTE FOR PARTS LIST

1.
Parts for which "nsp" is indicated on this table cannot be supplied.
2.
When ordering of part, clearly indicate "1" and "I" (i) to avoid mis-supplying.
3.
Ordering part without stating its part number can not be supplied.
4.
Part indicated with the mark " " is not illustrated in the exploded view.
5.
Not including General-purpose Carbon Film Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)
6.
Not including General-purpose Carbon Chip Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)
WARNING:
Parts marked with this symbol z have critical characteristics.
Use ONLY replacement parts recommended by the manufacturer.
Resistors
Ex.:
RN
14K
Type
Shape
and per-
formance
RD : Carbon
2B : 1/8 W
RC : Composition
2E : 1/4 W
RS : Metal oxide film
2H : 1/2 W
RW: winding
3A : 1 W
RN : Metal film
3D : 2 W
RK : Metal mixture
3F : 3 W
3H : 5 W
Resistance
1 8
2
1800ohm=1.8kohm
Indicates number of zeros after effective number.
2-digit effective number.
1 R
2
1.2ohm
1-digit effective number.
2-digit effective number, decimal point indicated by R.
: Units: ohm
Capacitors
Ex.:
CE
04W
Type
Shape
Dielectric
and per-
strength
formance
CE : Aluminum foil
0J : 6.3 V
electrolytic
1A : 10 V
CA : Aluminium solid
1C : 16 V
electrolytic
1E : 25 V
CS : Tantalum electrolytic
1V : 35 V
CQ : Film
1H : 50 V
CK : Ceramic
2A : 100 V
CC : Ceramic
2B : 125 V
CP : Oil
2C : 160 V
CM: Mica
2D : 200 V
CF : Metallized
2E : 250 V
CH : Metallized
2H : 500 V
2J : 630 V
Capacity (electrolyte only)
2 2
2
2200 F
Indicates number of zeros after effective number.
2-digit effective number.
Units: F.
Capacity (except electrolyte)
2 2
2
2200pF=0.0022 F
Indicates number of zeros after efective number.
(More than 2)
2-digit effective number.
Units:pF
When the dielectric strength is indicated in AC,"AC" is included after the dieelectric strength value.
2E
182
G
Power
Resist-
Allowable
Others
ance
error
F :
1%
P : Pulse-resistant type
G :
2%
NL : Low noise type
J
:
5%
NB : Non-burning type
K :
10%
FR : Fuse-resistor
M :
20%
F : Lead wire forming
1H
3R2
M
Capacity
Allowable
Others
error
F :
1%
HS : High stability type
G :
2%
BP : Non-polar type
J
:
5%
HR : Ripple-resistant type
K :
10%
DL : For change and discharge
M :
20%
HF : For assuring high requency
Z :
80%
U : UL part
: - 20%
C : CSA part
P : +100%
W : UL-CSA part
C :
0.25pF
F : Lead wire forming
D :
0.5pF
= : Others
DP-200USB
FR
BP
2 R
2
2.2 F
1-digit effective number.
2-digit effective number, decimal point indicated by R
Units: F.
2 2
1
220pF
Indicates number of zeros after effective numver.
(0 or 1)
2-digit effective number.
Units:pF
20