Optical Parts Disassemblies
b
Relay Lens-Out disassembly
1
A
Remove 2 screws
(M2.5x6) and pull the Relay Lens-Out ass'y upward.
2
B
Remove 2 screws
(M2x4) to take the Lens off from the holder.
Note:
There is no mounting direction of the lens.
n
Polarized Glass-In removal
1
Remove each screw (M2.5x6) and pull the Polarized Glass-In ass'y
upward.
2
Unhook the stoppers and take the glass off upward.
A
A
Fig.5-
1
Fig.6-
1
-16-
Holder
Relay Lens-Out
* Should be places the glass as the
film attached side comes to the
prism side.
B
B
Fig.5-
2
Phase Sheet
Polarized Glass-In
Hooks
Fig.6-
2