Mechanical Disassemblies
,
Optical Unit removal (2)
Step from previous procedure.
3
C
Remove 6 screws
(M3x8) to take the Optical Unit upward upward off.
To mount optical unit, mount optical unit first then mount the Lamp assembly
and Lamp Cover.
.
Power and P.F. Board removal
1
A
Remove 4 screws
(T3x6), 4 screws
take the Power Board ass'y upward off.
2
C
Remove 4 screws
(M3x6) to take the P. F. Board
from the Power Board.
3
D
Remove 3 screws
(M3x6) to take the Power
Board holder from the Cabinet Bottom.
C
C
C
C
B
(T3x8) to
C
B
D
-12-
C
C
Optical unit
C
C
C
B
B
B
P. F. board
A
A
A
A
D
D
Fig.8
-2
Power board
Fig.9