Expansion Vessel - Vaillant TURBOmax Pro 28 Instructions For Installation And Servicing

Wall hung room sealed fan assisted combination boilers
Table of Contents

Advertisement

Initial system pressure (bar)
Pressure relief valve setting (bar)
Total water content of system
litres
For system volumes other than those given above,
multiply the system volume by the factor across
Table R.2: Sizing of additional expansion vessel
25
50
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
475
500
GENERAL REQUIREMENTS
Vessel Volume [L]
1.0
1.5
3.0
2.7
3.9
5.4
7.8
10.9
15.6
13.6
19.5
16.3
23.4
19.1
27.3
21.8
31.2
24.5
35.1
27.2
39.0
30.0
42.9
32.7
46.8
35.7
50.7
38.1
54.6
40.9
58.5
43.6
62.4
46.3
66.3
49.0
70.2
51.8
74.1
54.5
78.0
0.109
0.156

Expansion vessel

The 28 kW boiler incorporates a
10 litre expansion vessel which is
suitable for a sealed heating system
with a maximum water content of
100 litres.
If the nominal capacity of the built in
expansion vessel is not sufficient for
the heating system (for instance in
case of modernisation of old open
systems) an additional expansion
vessel can be installed external to the
boiler. It should be fitted in the return
pipe as close as possible to the boiler
in accordance with BS 5449: Part 1.
Guidance on the sizing of an
additional expansion vessel is given
in Table R.2.