Installation And Service Check List - Hallmark Variable Speed 2 Stage Installation And Operation Instruction Manual

Oil fired furnace variable speed 2 stage ecm motor
Table of Contents

Advertisement

Furnace Model: _______________________
Installation Date: ______________________
Installer Name: ________________________
Furn
ace Installation
Furnace level and in solid contact with floor?
Furnace and burner wired per wiring diagram and National Electric Code? 120VAC wiring Type_____ Size _____
AWG
Burner sealed to furnace? Mounting nuts tight?
Space is large enough to provide required clearances?
NFPA 31 Installation of Oil Burning Equipment followed?
Local, state and national codes, laws, regulations and ordinances followed?
Ven
t System
Existing chimney and vent system inspected to NFPA 211 and in good condition?
New vent pipe installed and properly sealed?
Vent size checked against furnace manual and codes?
Duc
t Work
Return and supply ducts checked for size based on furnace air flow and ACCA Manual D?
All ducts sealed and insulated as required?
Burn
er Operation
Burner Model: __________________ Nozzle: _______GPH _______Deg. _______Type_______
Burner Pump Pressure: ______________
Fuel filter and fuel lines installed and inspected as per burner manual?
Air bled from oil piping? Piping checked for leaks?
Burner started, adjusted and tested per burner manual?
Furn
ace Operation
Thermostat heat anticipator set per burner manual instructions?
Temperature rise through the furnace checked 75
Blower motor amperage does not exceed rated full load amperage?
Clean air filter installed?
Limit control tested for proper operation?
Furnace observed going through several operational cycles for proper operation?
Post
Installation
Reviewed owners' information in this manual with owner or maintenance personnel and instructed to keep for future
reference?
Properly filled in and returned warranty registration card to Boyertown Furnace Co. Inserted burner manual
instructions with furnace manual for future use?
30

Installation and Service Check List

Serial No.: ______________________
Phone No.: ______________________
0
F maximum and blower speed adjusted as required?