Siemens SIMATIC FS600 Instruction Manual page 14

Table of Contents

Advertisement

DZ = Detection zone, max. 2,15 m / 4 m
WF = Warning zone, max. 15 m
a
= Maximum registration of measurement values,
max. 50 m
b
= Detection zone programmed
in the SIMATIC FS600
Laser Scanner
(example)
c
= Warning zone programmed
in the SIMATIC FS600
Laser Scanner
(example)
d
= Configurable detection
zone and warning zone
expansion (-5 °)
e
= Configurable detection
zone and warning zone
expansion (+5 °)
f
= Object in the detection zone
Fig. 2.1-1:
A laser diode coupled with transmitter optics produces focused light pulses. These
pulses are projected across the monitored surface by a rotating mirror in such a way that
a light pulse is triggered in each of the angle segments within 40 ms (scanning rate: 25
scans/s).
Fig. 2.1-2:
The SIMATIC FS600 Laser Scanner can detect people up to a distance of 4.0 m e.g.
2.15 m – even if they are wearing very dark clothing or exhibit a low degree of
reflectance. Dangerous movements are brought to a standstill by two failsafe
semiconductor outputs.
14
d
The 190° angle range of the SIMATIC FS600 Laser Scanner is divided
into 0.36° angle segments.
Functional principle of the SIMATIC FS600 Laser Scanner
c
b
SF
WF
a
f
e