Jade RJCT30 Installation Instructions Manual

Jade sealed gas cooktop

Advertisement

Quick Links

C
MODELS:
PLEASE READ THIS MANUAL COMPLETELY AND CAREFULLY BEFORE PROCEEDING.
NOTE TO THE INSTALLER: Please leave this manual with the cooktop for the consumer.
NOTE TO THE CONSUMER: Please retain this manual for future reference.
The installation of this appliance must conform with local codes or, in the absence of
local codes, with the National Fuel Gas Code ANSI Z223.1 - latest edition. If in-
stalled in Canada, installation must conform with local codes, or with CAN/CGA
B149.1, Natural Gas Installation Code or CAN/CGA B149.2 Propane Gas Installa-
tion Code.
This appliance must be electrically grounded in accordance with local codes or, in
the absence of local codes, with the National Electrical Code, ANSI/NFA 70 - latest
edition. In Canada, it must be electrically grounded in accordance with local codes
or with CSA C22.1 Canadian Electrical Code Part 1.
Important Safety Instructions ............................................................ 2
Unpacking and Inspection ................................................................. 2
RJCT Model Configuration and Specifications .................................. 3
Clearances from Combustible Surfaces ............................................ 4
Ventilating Hood Recommended Size................................................ 4
Installation Layout ............................................................................. 5
Gas Connection ................................................................................ 6
Electrical Connection ..................................................................... 7-8
Initial Startup and Burner Adjustment ................................................ 9
7355 E. SLAUSON AVENUE, COMMERCE, CALIFORNIA 90040
P/N
2400080000
06/03
INSTALLATION
US
INSTRUCTIONS
JADE SEALED GAS COOKTOP
RJCT30, RJCT36,
RJCT48, RJCT60
IMPORTANT
CONTENTS
MADE IN USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RJCT30 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Jade RJCT30

  • Page 1: Table Of Contents

    INSTALLATION INSTRUCTIONS JADE SEALED GAS COOKTOP MODELS: RJCT30, RJCT36, RJCT48, RJCT60 PLEASE READ THIS MANUAL COMPLETELY AND CAREFULLY BEFORE PROCEEDING. NOTE TO THE INSTALLER: Please leave this manual with the cooktop for the consumer. NOTE TO THE CONSUMER: Please retain this manual for future reference.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS safety WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 3: Rjct Model Configuration And Specifications

    AND SPECIFICATIONS safety BACK GUARD (OPTIONAL) FOR USE WHEN INSTALLED AGAINST COMBUSTIBLE REAR WALLS MODEL DIM “A” ISLAND BACK TRIM STANDARD RJCT30 FOR USE ONLY IN PENINSULA RJCT36 OR ISLAND TYPE INSTALLATION RJCT48 9 1/2 “A” RJCT3080A BODY BODY DEPTH 25 1/2 "A"...
  • Page 4: Clearances From Combustible Surfaces

    12” from rear wall, 6” from side cabinets (18” recommend a minimum 30” distance from the above cooking surface). bottom of the hood to the cooktop surface. Because of the high burner input rate of the Jade Recommended Size Ventilating Hood Minimum...
  • Page 5: Installation Layout

    ANGLE SUPPORT SUPPLIED WITH APPLIANCE BACK GUARD OPTIONAL SEE DETAIL ISLAND BACK TRIM STANDARD ''X'' 9 1/2 9 1/2 MODEL RJCT30 DSCT-30 29 5/8 SIDE TRIM RJCT48 DSCT-36 35 5/8 RJCT60 DSCT-48 46 5/8 SIDE TRIM COUNTER SIDE OF UNIT...
  • Page 6: Gas Connection

    GAS CONNECTION operation This appliance can be used with natural gas or LP gas. It is shipped from the factory adjusted for use with the gas specified on the nameplate. (See page 4 of the User Manual, for the location of the nameplate.) Please note that this appliance is not field convertible.
  • Page 7: Electrical Connection

    ELECTRICAL CONNECTION operation The Jade Gas Cooktop requires a 120 volt, 60 hertz, single phase, individual and properly grounded branch circuit. The circuit must be protected with a 10 amp circuit breaker or time-delay fuse. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 8 RJCT3080A RJCT3680A RJCT3683A RJCT3681A RJCT4883A RJCT4881A...
  • Page 9: Initial Startup And Burner Adjustment

    INITIAL STARTUP AND ADJUSTMENT operation The air for combustion and ventilation is supplied PLEASE REMEMBER: These burners produce through the front of the cooktop. The air is a lot of heat at the HI setting. DO NOT exhausted upward. Do not obstruct the flow of OPERATE THE BURNERS WITHOUT combustion and ventilation air.

This manual is also suitable for:

Rjct36Rjct48Rjct60