Service Navigation; Introduction; About Lens Block; Note: When Replacement Feram(Ic6003) On The Main P.c - Panasonic Lumix DMC-LX5P Service Manual

Table of Contents

Advertisement

3 Service Navigation

3.1.

Introduction

This service manual contains technical information, which allow service personnel's to understand and service this model.
Please place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
3.2.

About lens block

• The image sensor (CCD) unit which are connected to the lens unit with 3 screws. These screws are locked with the screw lock-
ing glue, after performing the Optical tilt adjustment.
• During servicing, if one of CCD fixing screws are loosened or removed, the Optical tilt adjustment must be performed.
About the Optical tilt adjustment, refer to the "9.3.2 Adjustment Specifications" for details.
3.3.
Note: When replacement FeRAM(IC6003) on the main P.C.B.
• After replacing the FeRAM(IC6003), it is necessary to use the adjustment software "DIAS" and "Adjustment Boot Software" to
allow the "Initialization".
• These software are available at "TSN Website". To download, click on "Support Information from NWBG/VDBG-AVC".
3.4.

General Description About Lead Free Solder (PbF)

The lead free solder has been used in the mounting process of all electrical components on the printed circuit boards used for this
equipment in considering the globally environmental conservation.
The normal solder is the alloy of tin (Sn) and lead (Pb). On the other hand, the lead free solder is the alloy mainly consists of tin
(Sn), silver (Ag) and Copper (Cu), and the melting point of the lead free solder is higher approx.30°C (86°F) more than that of the
normal solder.
Distinction of P.C.B. Lead Free Solder being used
Service caution for repair work using Lead Free Solder (PbF)
• The lead free solder has to be used when repairing the equipment for which the lead free solder is used.
(Definition: The letter of "PbF" is printed on the P.C.B. using the lead free solder.)
• To put lead free solder, it should be well molten and mixed with the original lead free solder.
• Remove the remaining lead free solder on the P.C.B. cleanly for soldering of the new IC.
• Since the melting point of the lead free solder is higher than that of the normal lead solder, it takes the longer time to melt the
lead free solder.
• Use the soldering iron (more than 70W) equipped with the temperature control after setting the temperature at 350±30°C
(662±86°F).
Recommended Lead Free Solder (Service Parts Route.)
• The following 3 types of lead free solder are available through the service parts route.
RFKZ03D01KS-----------(0.3mm 100g Reel)
RFKZ06D01KS-----------(0.6mm 100g Reel)
RFKZ10D01KS-----------(1.0mm 100g Reel)
Note
* Ingredient: tin (Sn) 96.5%, silver (Ag) 3.0%, Copper (Cu) 0.5%, Cobalt (Co) / Germanium (Ge) 0.1 to 0.3%
3.5.

Important Notice 1:(Other than U.S.A. and Canadian Market)

1. The service manual does not contain the following information because of issues servicing to component level without neces-
sary equipment/facilities.
a. Schematic diagram, Block Diagram and P.C.B. layout of MAIN P.C.B..
b. Parts list for individual parts for MAIN P.C.B..
When a part replacement is required for repairing MAIN P.C.B., replace as an assembled parts. (MAIN P.C.B.)
2. The following category is/are recycle module part. please send it/them to Central Repair Center.
• MAIN P.C.B. (VEP56112A: P/PC/PU/EE/GC/GD/GK/GN/GT/SG)
• MAIN P.C.B. (VEP56112B: EB/EF/EG/EP)