Local Codes; Product Features; Unpacking - Desa VDCFTNB Owner's Operation And Installation Manual

Unvented (vent-free) gas compact classic hearth dual burner fireplace
Table of Contents

Advertisement

Install and use fireplace with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel
Gas Code ANSI Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
SAFETY PILOT
This fireplace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room fireplaces. The ODS/pilot
shuts off the fireplace if there is not enough
fresh air.
PIEzO IGNITION SYSTEM
This fireplace has a piezo ignitor. This sys-
tem requires no matches, batteries or other
sources to light fireplace.
1. Remove fireplace and hood from carton.
Log is wrapped and inside fireplace. Do
not remove at this time.
2. Remove all protective packaging applied
to fireplace for shipment.
3. Make sure your fireplace includes one
hardware packet.
4. Check fireplace for any shipping damage.
If fireplace is damaged, call DESA Heat-
ing, LLC at 1-866-672-6040 for replace-
ment parts before returning to dealer.
REMOvING CERAMIC bRICK
LINERS (IF EqUIPPED)
WARNING: Ceramic brick
liners are located behind upper
louver and must be removed
before lighting fireplace.
123502-01C

loCal CoDEs

pRoDUCT FEaTUREs

UNpaCkiNG

www.desatech.com
State of Massachusetts: The installation
must be made by a licensed plumber or
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters shall
provide to each purchaser a copy of 527
CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in the
Commonwealth of Massachusetts.
THERMOSTATIC HEAT CONTROL
FOR THERMOSTAT-CONTROLLED
MODELS
Thermostat-Controlled models have a ther-
mostat sensing bulb and a control valve.
The thermostat will automatically modulate
the heat output to maintain a consistent
room temperature. This results in greater
fireplace comfort. This can also result in
lower gas bills.
1. Remove screws from top louver and care-
fully remove louver (see Figure 2).
2. Remove ceramic brick liners with protec-
tive packaging. The brick liners will be
installed later.
3. Remove yellow sticker from top of fire-
box.
4. Replace top louver using screws removed
in step 1.
Wrapped
Brick Liners
Top Louver
Screws
Figure 2 - Removing Brick Liners
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

VdcftpbCdcfpraDcdfnraVdcfrpbVdcfrnbCdcfnra

Table of Contents