FIREPLACE CLEARANCES

WARNING: Maintain the
minimum clearances shown
in Figure 7. If you can, provide
greater clearances from floor,
ceiling and joining wall.
If your fireplace is to be used with an optional
mantel, the installation instructions included
with your mantel shows an CSA approved
method of attaching the fireplace/mantel sys-
tem to a wall. IMPORTANT: Only use optional
cabinet or corner mantels specified in this
manual. Purchase the optional mantel from
your dealer (see Accessories, page 38).
If your fireplace is to be recessed into the wall,
see Built-In Fireplace Installation on page 10
to secure your fireplace into the wall.
CAUTION: If you install the
fireplace in a home garage
• fireplace pilot and burner must
be at least 18" above floor.
• locate fireplace where moving
vehicle will not hit it.
For convenience and efficiency, install fire-
place
• where there is easy access for operation,
inspection and service
• in coldest part of room
An optional blower kit is available from your
dealer. See Accessories, page 38. If planning
to use blower, follow instructions provided with
blower for power source.
Minimum Clearances For Side
Combustible Material, Side Wall and
Ceiling
A. Clearances from the side of the fireplace
cabinet to any combustible material and
wall should follow diagram in Figure 6.
Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3
/
1
2
bustible material must be 4" from the side
of the fireplace opening (see Figure 7).
10
iNsTallaTioN
" from the wall. This com-
www.desatech.com
Continued
B. Clearances from the top of the fireplace
opening to the ceiling should not be less
than 36".
C. For mantel clearances, see Figure 11 on
page 12.
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
Top 36", Left and Right Sides 6",
Bottom and Rear 0", Front 36"
*Minimum 16" from Side Wall
Figure 7 - Minimum Clearance for
bUILT-IN FIREPLACE INSTALLATION
Built-in installation of this fireplace involves
installing fireplace into a framed-in enclosure.
This makes the front of fireplace flush with wall.
An optional trim kit accessory is available (see
Accessories, page 38). Trim will extend past
sides of fireplace approximately 1/2". This will
cover the rough edges of the wall opening. If
installing a built-in mantel above the fireplace,
you must follow the clearances shown in Figure
11, page 12. Follow the instructions below to
install the fireplace in this manner.
Height
Front Width
Depth
1. Frame in rough opening. Use dimensions
shown in Figure 8, page 11, for the rough
opening. If installing in a corner, use
dimensions shown in Figure 9, page 11,
for the rough opening. The height is 26
which is the same as the wall opening
above.
Example
Combustible to Wall
Actual
26"
26
/
"
3
4
14
/
"
1
4
*
Framing
26
/
"
7
8
26
/
"
7
8
15
/
"
1
4
/
"
7
8
123502-01C

Advertisement

Table of Contents
loading

This manual is also suitable for:

VdcftpbCdcfpraDcdfnraVdcfrpbVdcfrnbCdcfnra

Table of Contents