InfoSight LabeLase LL2800 Basic Operations & Maintenance Manual

Tag printer

Advertisement

Quick Links

InfoSight
® ® ® ®
LabeLase
28XX Tag Printer
Basic Operations & Maintenance Manual
LL2800, LL2856, LL2852
Revision B
th
15
, October, 2007
INFOSIGHT CORPORATION
20700 U.S. Route 23
P.O. Box 5000
Chillicothe, Ohio 45601 USA
+1 (740) 642-3600 Tel. (M-F 8am-5pm US Eastern Time Zone)
+1 (740) 642-4666 Emergency Service (outside normal business hours)
+1 (740) 642-5001 Fax.
www.infosight.com
Page 1 of 24
Copyright © 2003-2007 InfoSight Corporation All Rights Reserved

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LabeLase LL2800 and is the answer not in the manual?

Questions and answers

Summary of Contents for InfoSight LabeLase LL2800

  • Page 1 Chillicothe, Ohio 45601 USA +1 (740) 642-3600 Tel. (M-F 8am-5pm US Eastern Time Zone) +1 (740) 642-4666 Emergency Service (outside normal business hours) +1 (740) 642-5001 Fax. www.infosight.com Page 1 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 2: Copyright Information

    (including but not limited to lost profits) arising out of, or relating to this manual or the information contained in it, even if INFOSIGHT CORPORATION has been advised, knew, or should have known of the possibility of such damages.
  • Page 3: Software/Firmware License Agreement

    INFOSIGHT copyright notice. Additional copies may be made when authorized to do so in writing by INFOSIGHT. In addition to any other right of INFOSIGHT, INFOSIGHT has the right to terminate this license if the terms of this license are violated.
  • Page 4: Preface

    PREFACE The LABELASE® ® ® ® 28XX Tag Printer is fourth in the family of InfoSight laser tag markers. The LABELASE® ® ® ® 28XX series contains many new features, including: a higher internal processor clock speed, a PC-driven interface and the ability to print multilingual fonts.
  • Page 5: Table Of Contents

    Air Filter Removal and Replacement Customer Service Functional Block diagram Serial Port Connections Drawings and Parts Listings 18-20 Laser Safety Declaration of Conformity Common Setup Printer Configuration Values Manual Revision History Page 5 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 6: System Startup

    The default password for new installations is blank (no data, no spaces). A new password should be created before printer is commissioned for regular operator use. Page 6 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 7: Loading New Tags

    STOP button is returned to the OUT position by pulling red button. If necessary, tag stock can be manually fed into the printer by pressing the FEED button located above the large red E-STOP button. Page 7 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 8: Printing A Tag

    CAUTION: DO NOT GRIP THE TAG STOCK BY ITS EDGES WHEN FEEDING INTO THE PRINTER. PROTECT YOUR HANDS AND FINGERS FROM THE SHARP EDGES OF THIN METAL TAG STOCK AT ALL TIMES. Page 8 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 9: Labelase® Producer™ Software

    Prints all PC-installed fonts, including multi-byte characters for Asian languages. User-selectable download of message data from a host computer via RS-232, network TCP/IP, or network file transfer. A wide selection of communications protocols includes InfoSight Extended, emulation of Zebra and Intermec standard printers, and simple comma or tab-separated, flat-file formats.
  • Page 10: Printer Configuration & Laser Settings

    Increase laser speed (move slider bar to LIGHTER). Create darker easier-to-read characters by using BOLD font instead of a larger font size. ARIAL BLACK is an especially efficient font for creating easy-to-ready text. Page 10 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 11 When inserting graphics and logos, try to keep the X-scale and Y-scale factors close to 1. The original graphics BMP file can be re-sized in a common application such as MS PAINT. Page 11 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 12: Best Practices And Helpful Hints

    BEST PRACTICES AND HELPFUL HINTS To facilitate sharing of best practices among users, InfoSight has created an online DISCUSSION FORUM. You may access the forum via our home webpage or directly at http://www.infosight.com/forums/ BASIC TROUBLE SHOOTING Service during normal business hours (Monday-Friday, 8am-5pm): 888-642-3600 or 740-642-3600...
  • Page 13: Normal Maintenance & Servicing

    DO NOT USE COMPRESSED AIR TO CLEAN OPTICS! DO NOT USE EYE GLASS WIPES CONTAINING ALCOHOL! For optics that are severely contaminated or damaged, contact InfoSight for replacement. Page 13 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 14: Air Filter Removal And Replacement

    Carefully blow any lint or dust off the filter, or gently wash it in soap and water. Dry the filter thoroughly before reinstalling. Be sure to replace the filter element into the cover plate correctly. It fits only one way. Page 14 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 15: Customer Service

    Call 1-888-642-3600, or outside the USA call 740-642-3600. Emergency Service After regular business hours, call 740-642-4666. On-Site Service InfoSight Corporation can dispatch a Field Service Engineer to your facility to perform equipment start-up, repair, maintenance, and training. Service Contracts Periodic scheduled on-site maintenance, technical service and extended warranties can be arranged by contacting Customer Service at the number below.
  • Page 16: Functional Block Diagram

    Functional Block Diagram Page 16 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 17: Serial Port Connections

    Note: Handshake protocol is XON / XOFF. Communications adapters such as USB to RS232 must support XON / XOFF. XON is DC1 CTL-Q or 11h or 17 decimal XOFF is DC3 CTL-S or 13h or 19 decimal Page 17 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 18: Drawings And Parts Listings

    Dead ITM14840 POWER-SUPPLY,LASER,30V,16A,CE MARKED, ITM07243 SWITCH,KEYLOCK,SECURITY ITM07477 FUSE,TIME-DELAY,FNM15 Misc ITM10871 FILTER,REPLACEMENT,FOR ITM10870 GUARD,5/PK ITM01213 FAN,MUFFIN,120VAC,14W,2900RPM,112CFM ( Please Request BOM26244 to receive quote for the entire spares list. ) Page 18 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 19 Page 19 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 20 Page 20 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 21: Laser Safety

    Qualified Laser Service/Safety Technician! Because of the Class 4 classification, InfoSight will provide such a person to be available to the end user of this marker. The nominal power output of the laser used is 10 watts, with a maximum peak power output of 30 watts. It is a C02 infrared (invisible) laser with a wavelength of 10.57 to 10.63 microns.
  • Page 22: Declaration Of Conformity

    Standard(s) set forth in this document. InfoSight produces laser systems within one of two classes as identified and classified by the CDRH. These are Class I and Class IV. (see CDRH 21 CFR (J) 1040.1 - 1040 .5). End user of the equipment should be familiar with ANSI, CDRH and OSHA standards for radiation emitting devices as they apply to them also.
  • Page 23: Common Setup Printer Configuration Values

    Galvo Home Delay 60 Galvo Offset Laser Speed 9060 Min Speed Max Speed Laser Off Tickle Laser Duty Cycle Num Lasers Tear off Burn Loc 3.96 3.96 3.96 Page 23 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...
  • Page 24: Manual Revision History

    Initial Release 10/15 /2007 Revision B Correction to Spares List - ITM24343 Added Manual Revision History Common Setup Printer Configuration Values Removed Single Feed instructions Corrected Coil Loading instructions Page 24 of 24 Copyright © 2003-2007 InfoSight Corporation All Rights Reserved...

This manual is also suitable for:

Labelase ll2856Labelase ll2852

Table of Contents