Product Summary
The NX-450 (white) and NX-451 (brown) Door/Win-
dow Sensors can be installed on doors, windows, or
many other objects that open and close. The sensors
transmit signals to the control panel when a magnet
mounted near the sensor is moved away from or closer
to the sensor.
The sensors include an input that accepts external
hardwired devices such as flush-mounted door/win-
dow contacts.
Installation Guidelines
Use the following guidelines for installing Door/Win-
dow sensors.
Mount the sensor on the door frame and the mag-
net on the door (see Figure 1). If the sensor is to be
used on double doors, mount the sensor on the
least-used door and the magnet on the other door.
Figure 1. Sensor and Magnet Locations
Sensor
Magnet
If possible, locate sensors within 100 feet of the
panel. While a transmitter may have a range of
500 feet or more out in the open, the environment
at the installation site can have a significant effect
on transmitter range. Sometimes a change in sen-
sor location can help overcome adverse wireless
conditions.
Make sure the alignment arrow on the magnet
points to the alignment mark on the sensor (see
Figure 2).
Doorframe
2 - AAA Batteries
Figure 2. Aligning the Door/Window Sensor
and Magnet
Place sensors at least 5 inches above the floor to
avoid damaging them.
Avoid mounting sensors in areas where they will
be exposed to moisture or where the operating
temperature (10°-120°F) will be exceeded.
Use spacers (not included) to keep sensors and
magnets away from metal or metallic surfaces
such as foil wallpaper.

Materials Needed

#6 flathead screws
Screwdriver or brad driver

Installing the Sensor

1.
Remove the sensor cover by pressing the button
on the narrow end.
2.
Remove the batteries to access the mounting
holes.
3.
Mount the sensor base with two #6 flathead
screws at the locations shown in Figure 3. If you
need to connect external switches, they should be
installed at this point. Use the procedure for con-
necting external switches.
NX-450, NX-451 Door/Window Sensors
Align Arrow
and Mark
8959G16B.DS4