Fireplace & Hearth Dimensions - Monessen Hearth DLY18 Installation And Operating Instructions Manual

Unvented gas log heater or vented decorative appliance natural gas or propane/lpg control type: manual, or milli-volt
Table of Contents

Advertisement

This appliance has been specifically tested and design certified for installa-
tion only in a solid-fuel burning fireplace including factory-built UL127 fire-
places and masonry fireplaces, or approved ventless firebox enclosure. (see
below)
Use manufacturer's installation and clearance requirements as defined in their manual.
The DLY/GLY Series unvented room heater is approved for installation into the following unvented
fireplaces:
The DLY/GLY Series unvented room heater may also be installed into a Ventless Firebox Enclo-
sure for Gas Fired Decorative Type Unvented Room Heaters per IAS Requirement No. 2-97, as
long as firebox hearth dimensions meet the minimum hearth dimensions shown below.
DLY18/GLY18
DLY24GLY24
DLY30/GLY30
Figure 2: Hearth Minimum Dimension for Solid Fuel Burning
FIREPLACE and HEARTH DIMENSIONS
Monessen
GC/GR 32
GC/GR 36
GC/GR 42
D
C
Model
A
17.5"
21"
25"
Fireplaces and UL127 Factory Built Fireplaces
18
24
X
X
X
X
X
A
B
B
C
D
13.25"
27"
17"
14"
29.5"
17"
14"
33.5"
17"
30
X
9

Hide quick links:

Advertisement

Table of Contents
loading