Alarm Recording (Emergency Recording); Principle Of Alarm Recording; Alarm And Display Methods During; Alarm Recording - Panasonic AG-TL350B Operating Instructions Manual

Time lapse recorder
Table of Contents

Advertisement

Alarm Recording (Emergency Recording)

When an emergency occurs at the monitoring site during prolonged monitoring and recording, the alarm function
is automatically triggered, and alarm recording is performed.

Principle of alarm recording

Alarm input
Tape start
Recording

Alarm recording

Time lapse mode
Alarm mode
When an alarm signal is supplied by an alarm sensor
(door or intercom switch, etc.) during recording in a
time lapse mode, the recording speed is switched to
the 3- or 6-hour mode and the details of the state of
emergency are faithfully recorded.

Alarm and display methods during

alarm recording
PULL OPEN
TRACKING /
V-LOCK
RESET
When an alarm signal is supplied, the alarm display
lamp functions as follows.
On
Alarm
lamp
Alarm input
Alarm reset
input
17-11-00
10:14:30 A
TV monitor
Alarm reset input
Tape end
Recording
Time lapse mode
(3H/6H)
EJECT
REC REVIEW
REC
REC
COUNTER /
TIME MODE
SEARCH
ALARM
ALARM display lamp
Flashing
Off
switch is
pressed.
Display
switch to
"3H" or "6H."
3H
"A" display
appears
Connecting the alarm input
connector
Alarm switch
Alarm reset switch
Alarm recording starts when the alarm switch is set
on. When the alarm reset switch is set ON after
recording has started, alarm recording is released
and operation is returned to the original time lapse
recording mode.
Alarm recording can be released by pressing the
STOP button during alarm recording.
However, it cannot be released even by pressing the
STOP button if the MENU/REC LOCK switch is at
REC LOCK or INT is lighted on the display.
Alarm recording can be automatically reset without
supplying the alarm reset input signal.
The reset time can be set for 30 sec., 1.0, 2.0, 3.0,
5.0 or 10 minutes.
Another option is alarm recording only while the alarm
input signal is supplied.
Alarm recording is also possible as far as the end
of the tape.
19
Alarm switch
CAMERA
SW OUT
ALARM RESET IN
AC IN
ALARM IN
COMMON
4 V – 14 V
IN
AUDIO
OUT
TAPE END OUT
WARNING/
REC IN
REC OUT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ag-tl350e

Table of Contents