Diagnostic Error Code
025-198-XXX
IDE interface test aborted
025-199-XXX
IDE interface test failed, cause unknown
030-000-XXX
SCSI interface Test Passed
030-00X-XXX
030-01X-XXX
SCSI interface failure
030-027-XXX
SCSI interface Configuration/Setup error
030-03X-XXX
030-04X-XXX
SCSI interface error
030-195-XXX
SCSI interface Test aborted by user
030-196-XXX
SCSI interface test halt, error threshold
exceeded
030-197-XXX
SCSI interface test warning
FRU/Action
1. If a component is called out, make sure
it is connected and/or enabled. See
Chapter 6, "Using the CMOS Setup
Utility," on page 51
2. Flash the system and re-test. See "Flash
update procedures" on page 184
3. Go to "Undetermined problems" on page
82
1. Go to "Undetermined problems" on page
82
2. Flash the system and re-test. See "Flash
update procedures" on page 184
3. Replace component under function test
No action
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
1. SCSI signal cable
2. Flash the system. See "Flash update
procedures" on page 184
3. SCSI device
4. SCSI adapter card, if installed
5. System board
1. SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the CMOS Setup
Utility," on page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test
Chapter 7. Symptom-to-FRU Index