Setting The Rf Link - Worcester 24CDi Instruction Manual

Digistat programmable 24 hour room thermostat system
Table of Contents

Advertisement

DIGISTAT
INSTALLATION
Digistat
Digistat
4. Remove the battery cover using a coin (Fig 4).
5. Install the 2 AA batteries provided (Fig 5).
6. Replace battery cover (fig 6).
Digistat +2RF
Radio Signal Range:
refer to Technical Data page
The range may be affected by
composition, density and number of walls
between the Programmer and Receiver
7. The Digistat is now installed and will automatically
start to control the room temperature according to
the pre-set program 1 as shown on page 8.
The display shows the correct time and date
which is automatically set together with the actual
room temperature.
OPERATING & INSTALLATION
12
INSTRUCTIONS
Receiver set up:
To set up the radio frequency (RF) link, the receiver
must be put into the LEARN MODE.
To set up the RF link, proceed as follows:
Digistat
1. Press the OVERRIDE button until the green light
is ON, the appliance is now running in central
heating mode.
2. To enter the LEARN MODE press and hold both
buttons 1 and 2.
The red light should flash for two seconds and
then go out, this signifies that the receiver is in the
LEARN MODE, release both buttons.
3. The red and green lights should both be ON.
Digistat
Transmitter set up:
1. Take the Digistat Programmer unit and stand
approximately two metres away from the boiler.
2. Remove the battery cover and fit the batteries.
The red light on the eceiver should flash for seven
seconds, this confirms that the RF signal is being
sent and received. After seven seconds the red
light will stop flashing and the green light will
come ON.
The Digistat Programmer is now linked to the
receiver on the boiler.
BOILER
DIGISTAT PROGRAMMABLE 24 HOUR
ROOM THERMOSTAT SYSTEM
8 716 114 518a (09.07)
DIGISTAT / RECEIVER
SETTING UP THE RF LINK