Mitsubishi Electric MUZ-GA50VA Service Manual page 47

Split-type, heat pump air conditioners
Hide thumbs Also See for MUZ-GA50VA:
Table of Contents

Advertisement

OPERATING PROCEDURE
2. Removing the inverter assembly, inverter P.C. board
and power board
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Remove the back panel.(Refer to 1.)
(3) Disconnect the following connectors;
<Electronic control P.C. board>
CN931 and CN932 (Fan motor)
CN795 (LEV)
CN661 (Discharge temperature thermistor, defrost
thermistor and outdoor heat exchanger
temperature thermistor)
CN663 (Ambient temperature thermistor)
CN681 (High pressure switch) (GA60VA-
<Noise filter P.C. board>
CN912 (R.V coil)
(4) Remove the compressor connector.
(5) Remove the screws fixing the relay panel.
(6) Remove the inverter assembly.
(7) Disconnect all connectors and lead wires on the electronic
control P.C. board.
(8) Remove the electronic control P.C. board from the inverter
assembly.
(9) Remove the screws fixing the power board assembly.
(10) Disconnect all connectors and lead wires on the power
board.
(11) Remove the power board from the inverter assembly.
(12) Disconnect all connectors and lead wires on the noise filter
P.C. board.
(13) Remove the noise filter P.C. board from the inverter
assembly.
3. Removing R.V. coil
(1) Remove the top panel, cabinet and service panel.
(Refer to 1.)
(2) Remove the back panel. (Refer to 1.)
(3) Disconnect the following connectors;
<Noise filter P.C. board>
CN912 (R.V coil)
(4) Remove the R.V. coil. (Photo 9)
Photo 4
, GA71VA)
E3
47
PHOTOS
Screws of the power board assembly
Screws of the relay panel

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Muz-ga60vaMuz-ga71va

Table of Contents