Selectinga Location - Monessen Hearth BFVF1M Installation, Operation And Maintenance Manual

Blue flame unvented room heaters with manual control
Table of Contents

Advertisement

S
A L
ELECTING
These heaters are shipped from the factory equipped for mounting on a
flat wall. A wall-mount template is provided with each heater to aid in
locating the heater on a wall. Maintaining at least the minimum spacing
to combustibles as illustrated by Figure 1 is required for safety. Using
the wall-mount template will help ensure that the required minimum
clearances between the heater and adjacent walls, floor, and ceiling are
maintained when mounting the heater on a wall.
The wall-mount anchors provided with each heater are for mounting the
heater to a hollow wall (wall area between studs.) If the heater is to be
mounted to a solid wall such as concrete or masonry, these wall-mount
anchors should not be used. Obtain appropriate solid wall-mount anchors
with number 10 mounting screws from your local hardware store.
The minimum clearances (see Figure 1) between combustible materials
and a wall mounted heater are:
Back - 0 inches (mount directly on wall)
Floor - 3 inches
Sides - 4 inches on each side of the heater
Top -
36 inches
Front - 48 inches
F
1
IGURE
CEILING LINE OR OTHER
CEILING LINE OR OTHER
COMBUSTIBLE SURFACE
COMBUSTIBLE SURFACE
4" 4"
MINIMUM
MINIMUM
SIDE WALL
SIDE WALL
OR OTHER
OR OTHER
COMBUSTIBLE
COMBUSTIBLE
SURFACE
SURFACE
MINIMUM TO TOP SURFACE OF
MINIMUM TO TOP SURFACE OF
CARPETING, TILE OR OTHER
CARPETING, TILE OR OTHER
COMBUSTIBLE MATERIAL.
COMBUSTIBLE MATERIAL.
(APPLIES TO ALL WALL MOUNTED HEATERS ONLY)
(APPLIES TO ALL WALL MOUNTED HEATERS ONLY)
OCATION
4" 4"
MINIMUM
MINIMUM
36"
36"
MINIMUM
MINIMUM
(SEE NOTE 1)
(SEE NOTE 1)
NOTES:
NOTES:
1. WALL MOUNTED HEATER SHOWN.
1. WALL MOUNTED HEATER SHOWN.
UNLESS NOTED OTHERWISE, ALL
UNLESS NOTED OTHERWISE, ALL
CLEARANCE DIMENSIONS SHOWN
CLEARANCE DIMENSIONS SHOWN
ALSO APPLY TO A HEATER MOUNTED
ALSO APPLY TO A HEATER MOUNTED
ON A FLOOR STAND.
ON A FLOOR STAND.
2. GAS PIPING NOT SHOWN.
2. GAS PIPING NOT SHOWN.
3" MIN.
3" MIN.
DO NOT PLACE COMBUSTIBLE
DO NOT PLACE COMBUSTIBLE
MATERIAL CLOSER THAN 48 INCHES
MATERIAL CLOSER THAN 48 INCHES
SIDE WALL
SIDE WALL
OR OTHER
OR OTHER
COMBUSTIBLE
COMBUSTIBLE
SURFACE
SURFACE
IN FRONT OF HEATER.
IN FRONT OF HEATER.
(SEE NOTE 1)
(SEE NOTE 1)
Danger: Do not install this
heater in any area where
gasoline or any combustible or
explosive material will be used
or stored. The flame from this
heater is exposed to the area
around the heater. Contact with
explosive
or
materials will lead to explosion
or fire.
53D9013. Rev 1 03/03
flammable
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bfvf3mBfvf2m