Monessen Hearth BFVF1M Installation, Operation And Maintenance Manual page 15

Blue flame unvented room heaters with manual control
Table of Contents

Advertisement

I
NSTALLATION AND
7. If the heater is to be equipped with an optional blower, install the
blower according to the instructions provided with the blower. (Note:
BFVF1M heaters cannot be equipped with a blower.)
8. Locate the two key-hole slots on the back of the heater. Align the
large openings of the key-hole slots with the mounting screws in
the anchors in the wall. Hang the heater on the two mounting screws
by positioning the heater so that the heads of the mounting screws
protrude into the large openings of the key-hole slots; let the heater
slide downward until the mounting-screw shanks are in the small
openings of the key-hole slots. Tighten the two upper mounting
screws into the wall anchors. See Figure 6.
9. Locate the two standoffs on back of the heater. Insert two screws
from the bag of fasteners through the holes in the standoffs. Tighten
the screws into the wall until the heater is firmly secured to the
wall. See Figure 6.
Proceed to Step 14.
F
H
REESTANDING
EATER
10. Attach the proper floor stand according to the instructions provided
with it. Model XFS Floor Stand is available from your local dealer.
11. Select a location which will maintain the minimum clearances from
the heater to combustible materials.
12. Remove the two front panel screws as shown by Figure 6 and
then remove the front panel from the heater by pulling the lower
portion of the front panel out and down.
13. If the heater is to be equipped with an optional blower, install the
blower according to the instructions provided with the blower. (Note:
BFVF1M heaters cannot be equipped with a blower.)
14. Install proper gas piping according the "
P
R
RESSURE
EQUIREMENTS
15. Turn the heater's control knob clockwise to "Off". Figures 2 and 3.
16. Turn the gas on at the shutoff valve. Use a soap-water solution or
liquid gas leak detector to check carefully for gas leaks at all fittings
from the shutoff valve to the heater's control valve located at the
top of the heater. If any leaks are found, turn the shutoff valve off
and repair all leaks before proceeding.
A
DJUSTMENT
I
O
A F
NSTALLED
N
G
AS
"
section of this manual.
S
LOOR
TAND
P
A
G
IPING
ND
AS
Danger: Excessive torque
(twisting) on the inlet fitting of this
heater may cause gas leaks at
one or more of the fittings inside
the heater.
Danger: Do not use candles,
matches or other ignition
sources when checking for gas
leaks.
Fuel gases are very
flammable and, in certain
concentrations, explosive.
Checking for leaks with an open
flame may lead to fire or
explosion which could cause
personal
injury,
damage, or death.
53D9013. Rev 1 03/03
property
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bfvf3mBfvf2m

Table of Contents