6-4 ANOTHER ELECTRIC COMPONENTS
Cooling is impossible
Compressor
doesn't run.
Running state of
Compressor is poor.
Cooling ability is poor
Fan motor
doesn't run.
Much frost are sticked
to the EVAPORATOR.
Check if current flows to
the following
components.
a. Thermostat
b. Starting devices
c. OLP
d. Compressor coil
e. Defrost Timer
f. Circuit parts
Check a starting
voltage.
Check if current flows
to starting devices.
Check current flowing
in sub-coil of
Compressor.
Check capacity of OLP.
The items described
above are normal.
Check current flowing
of the door S/W.
Check current flowing
in the Fan Motor.
Check the running
condition of Timer.
Check current flowing
of the following
components.
• Def Control Assy
Check current flowing
of the following
components.
• L-CORD, TE-PLATE
HEATER
Cause
Poor contacting and
gas leakage.
Shorted or broken.
Poor contacting
or shorted.
Coil shorted.
Poor contacting
or shorted.
Low voltage.
Poor contacting
and broken.
Shorted.
Lack of capacity.
Coil of Motor
Compressor.
Poor contacting.
Coil is shorted.
Running is poor.
(Coil is shorted.)
Shorted.
- 14 -
Replace
each component.
Raise the voltage.
Replace
each component.
Replace
the compressor.
Replace
each component.
Replace
each component.
Replace
each component.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents