OPERATING PROCEDURE
5. Removing outdoor fan motor
(1) Remove the cabinet and panels. (Refer to 1.)
(2) Disconnect the connectors for outdoor fan motor.
(3) Remove the propeller nut. (See Photo 7.)
(4) Remove the propeller. (See Photo 7.)
(5) Remove the screws fixing the fan motor. (See Photo 7.)
(6) Remove the fan motor.
6. Removing the compressor and 4-way valve
(1) Remove the cabinet and panels. (Refer to 1.)
(2) Remove the inverter assembly. (Refer to 2.)
(3) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
(4) Detach the welded part of the suction and the discharge
pipe connected with compressor.
(5) Remove the nuts of compressor legs.
(6) Remove the compressor.
(7) Detach the welded part of pipes connected with 4-way
valve. (See Photo 8.)
2
(0 MPa).
41
PHOTOS
Photo 6
Photo 7
Screws of the outdoor fan motor
Propeller
Propeller nut
Photo 8
Welded parts of 4-way valve
Outdoor heat
exchanger tempera-
ture thermistor
Defrost
thermistor