Item
Condition
5. Max deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
AG:1kHz/150mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
6.VOX 1
TEST CH: Center
Writing
AG:1kHz/45mV
7.QT deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
8.DQT deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
9.DTMF deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
10.MSK deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
ADJUSTMENT
Measurement
Test equipment
Terminal
Power meter
ANT
Deviation meter
SP/MIC connector
Oscilloscope
AG
AF VTVM
ANT
TK-3202L
Adjustment
Parts
Method
Programming
4.2kHz
Software:KPG-87D (According to
the larger +,–)
2.2kHz
(According to
the larger +,–)
Programming
0.75kHz
Software:KPG-87D
0.38kHz
0.75kHz
0.38kHz
3.0kHz
1.5kHz
3.1kHz
1.5kHz
Specifications/
Remark
±80Hz
±80Hz
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
±100Hz
±100Hz
19