Setting the startup preset

You can set the preset used at startup when this unit is turned
on. Make this setting on the
UTILITY 1
1. Press the MENU button to open the
page, and turn the MULTI JOG dial to select the
item.
2. Press the MULTI JOG dial to open the
screen.
3. Turn the MULTI JOG dial to set the preset used at startup.
Option
Function
LAST (default)
Startup with last used settings
PRESET 1
PRESET 2
Startup with the corresponding preset
settings
PRESET 3
PRESET 4
FACTORY
Startup with factory default settings
NOTE
The
item setting cannot be restored to the
STARTUP
factory default.
4. Press the MULTI JOG dial to confirm the selection and return
to the menu.

Calibrating the internal oscillator

The importance of calibration
This unit has an OCXO (oven-controlled crystal oscillator) that
provides 0.01ppm high-precision frequency output. However,
every clock generator, including this one, can normally be
expected to change over time.
In order to enable continued use with high-performance, this
unit has a function for calibrating the internal oscillator.
If you connect and input a 10MHz signal generated from
a GPS signal or a PPS signal, for example, to the dedicated
connector, the unit will recognize it
CALIBRATION INPUT
automatically and calibrate the internal clock.

Checking the unit firmware version

Follow these procedures to check this unit's firmware version.
Do this before updating the firmware, for example.
1. Press the MENU button repeatedly to open the
menu page, and turn the MULTI JOG dial to select the
2
item.
VERSION
24
TASCAM CG-1800/CG-1000
page.
menu
UTILITY 1
STARTUP
STARTUP MODE
UTILITY
2. Press the MULTI JOG dial to open the
The
screen shows information about the
VERSION
firmware version and build number.
3. Press the EXIT/CANCEL button to return to the menu
screen.
NOTE
When the
screen is open during step 2 above,
VERSION
press the MULTI JOG dial to switch to firmware updating.
For the latest information about updating firmware, visit
the TEAC Global Site (http://teac-global.com/).

Checking the error log

Follow these procedures to check the error log, which contains
information about past errors.
Check the error log from the
LOG
1. Press the MENU button repeatedly to open the
menu, and turn the MULTI JOG dial to select the
item.
LOG
2. Press the MULTI JOG dial to open the
In the error log, each error is shown on a separate page.
Error log page example
Error log number
1
These numbers are assigned to errors in order as they are
added to the log.
Error date and time
2
This shows when the error was added to the log.
Error summary
3
This shows the error code and signal affected as described
in the Overview of error codes table. (See "Overview of error
codes" on page 10.)
Signal that error affected
4
This shows the signal that the error affected.
Error result
5
This shows what happened because of the error.
Recovery date and time
6
This shows when the unit recovered from the error.
Recovery summary
7
This shows how the unit recovered from the error.
Recovery result
8
This shows what happened when the unit recovered.
screen.
VERSION
page.
page
LOG
ERROR
screen.
ERROR LOG